Failure to place a tunneled hemodialysis catheter due to malformation of right internal jugular vein draining to subclavian vein.

J Int Med Res

2 Department of Anesthesiology, the Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, China.

Published: June 2018

The right internal jugular vein (IJV) is an important access site for hemodialysis catheterization. Venous cannulation failure is usually caused by central venous stenosis and is rarely related to vessel malformation. We herein present a case of failure to place a tunneled hemodialysis catheter into the right IJV. The patient had an arteriovenous fistula in the right arm with inadequate flow and a history of multiple central venous catheterizations. The guidewire was repeatedly misplaced into the right subclavian vein (SV) regardless of the technique used. Computed tomography venography revealed that the inferior segment of the right IJV drained into the ipsilateral SV. To the best of our knowledge, this is the first report of catheterization failure due to abnormal drainage of the right IJV into the ipsilateral SV.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6023040PMC
http://dx.doi.org/10.1177/0300060518766649DOI Listing

Publication Analysis

Top Keywords

failure place
8
place tunneled
8
tunneled hemodialysis
8
hemodialysis catheter
8
internal jugular
8
jugular vein
8
subclavian vein
8
central venous
8
failure
4
catheter malformation
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!