A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Investigating elastic relaxation effects on the optical properties of functionalised calcium carbonate compacts using optics-based Heckel analysis. | LitMetric

Heckel analysis is a widely used method for the characterisation of the compression behaviour of pharmaceutical samples during the preparation of solid dosage formulations. The present study introduces an optical version of the Heckel equation that is based on a combination of the conventional Heckel equation together with the linear relationship defined between the effective terahertz (THz) refractive index and the porosity of pharmaceutical tablets. The proposed optical Heckel equation allows us to, firstly, calculate the zero-porosity refractive index, and, secondly, predict the in-die development of the effective refractive index as a function of the compressive pressure during tablet compression. This was demonstrated for five batches of highly porous functionalised calcium carbonate (FCC) excipient compacts. The close match observed between the estimated in-die effective refractive index and the measured/out-of-die effective THz refractive index supports the validity of the proposed form of the equation. By comparing the measured and estimated in-die tablet properties, a clear change in the porosity and hence, the effective refractive index, due to post-compression elastic relaxation of the FCC compacts, has been observed. We have, therefore, proposed a THz-based compaction setup that will permit in-line monitoring of processes during tablet compression. We envisage that this new approach in tracking powder properties introduced in this preliminary study will lead to the onset of further extensive and detailed future studies.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ijpharm.2018.04.043DOI Listing

Publication Analysis

Top Keywords

heckel equation
12
effective refractive
12
elastic relaxation
8
functionalised calcium
8
calcium carbonate
8
heckel analysis
8
thz refractive
8
tablet compression
8
estimated in-die
8
refractive
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!