A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Radiomics of CT Features May Be Nonreproducible and Redundant: Influence of CT Acquisition Parameters. | LitMetric

Radiomics of CT Features May Be Nonreproducible and Redundant: Influence of CT Acquisition Parameters.

Radiology

From the Departments of Medical Physics (R.B.), Radiation Oncology (S.S., M.V.V.), and Radiology (M.d.R.P.J.), Complejo Hospitalario Universitario de Albacete (CHUA), C/ Hnos Falcó 37, 02006 Albacete, Spain; Renewable Energy Research Institute, University of Castilla-La Mancha, Albacete, Spain (J.C.V., M.C.G.); and Mansilla Diagnóstico por Imagen, Albacete, Spain (F.M.L.).

Published: August 2018

Purpose To identify the reproducible and nonredundant radiomics features (RFs) for computed tomography (CT). Materials and Methods Two phantoms were used to test RF reproducibility by using test-retest analysis, by changing the CT acquisition parameters (hereafter, intra-CT analysis), and by comparing five different scanners with the same CT parameters (hereafter, inter-CT analysis). Reproducible RFs were selected by using the concordance correlation coefficient (as a measure of the agreement between variables) and the coefficient of variation (defined as the ratio of the standard deviation to the mean). Redundant features were grouped by using hierarchical cluster analysis. Results A total of 177 RFs including intensity, shape, and texture features were evaluated. The test-retest analysis showed that 91% (161 of 177) of the RFs were reproducible according to concordance correlation coefficient. Reproducibility of intra-CT RFs, based on coefficient of variation, ranged from 89.3% (151 of 177) to 43.1% (76 of 177) where the pitch factor and the reconstruction kernel were modified, respectively. Reproducibility of inter-CT RFs, based on coefficient of variation, also showed large material differences, from 85.3% (151 of 177; wood) to only 15.8% (28 of 177; polyurethane). Ten clusters were identified after the hierarchical cluster analysis and one RF per cluster was chosen as representative. Conclusion Many RFs were redundant and nonreproducible. If all the CT parameters are fixed except field of view, tube voltage, and milliamperage, then the information provided by the analyzed RFs can be summarized in only 10 RFs (each representing a cluster) because of redundancy.

Download full-text PDF

Source
http://dx.doi.org/10.1148/radiol.2018172361DOI Listing

Publication Analysis

Top Keywords

coefficient variation
12
rfs
9
radiomics features
8
acquisition parameters
8
test-retest analysis
8
concordance correlation
8
correlation coefficient
8
hierarchical cluster
8
cluster analysis
8
177 rfs
8