A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

New Approach of QuEChERS and GC-MS Triple-Quadrupole for the Determination of Ethyl Carbamate Content in Brazilian . | LitMetric

is a popular spirit produced in Brazil, obtained by distillation of fermented sugar cane. Among the contaminants arising from production, ethyl carbamate is a carcinogenic compound that occurs naturally in fermented foods and beverages; in Brazil, the maximum limit established by current legislation is 150 µg L. Quality control is usually performed using gas chromatography; however, robustness and reproducibility of quantitative results may be severely impaired, as the addition of 6-30 g L of sucrose is a common procedure for taste standardization, directly interfering in the results. This work describes the development of a novel method to improve ethyl carbamate quantification in using a new approach of QuEChERS extraction based on salting-out phenomenon, to effectively separate ethanol from sugar-containing water. Eighteen different brands of were analyzed. The proposed methodology was able to eliminate components that contaminate the sample flow path in the gas chromatography system, while improving precision and accuracy by using a triple-quadrupole approach, in comparison with the methodology usually employed: direct analysis of samples with no sample prep. Results indicate that this approach is more effective due to the removal of sugar content, with no impact in costs per analysis.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5897439PMC
http://dx.doi.org/10.3389/fnut.2018.00021DOI Listing

Publication Analysis

Top Keywords

ethyl carbamate
12
approach quechers
8
gas chromatography
8
approach
4
quechers gc-ms
4
gc-ms triple-quadrupole
4
triple-quadrupole determination
4
determination ethyl
4
carbamate content
4
content brazilian
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!