Background: Esophageal thermal injury is a feared complication of radiofrequency ablation for atrial fibrillation (AF). Rise in luminal esophageal temperature (LET) limits the ability to deliver radiofrequency energy on the posterior wall of the left atrium.
Objective: The purpose of this study was to evaluate the feasibility, safety, and efficacy of a mechanical esophageal deviation (ED) tool during AF ablation.
Methods: We evaluated 687 patients who underwent radiofrequency ablation for AF. In 209 patients, the EsoSure (Northeast Scientific) was used to deflect the esophagus away from the ablation site. Propensity score matching was performed to obtain 180 patients each in the ED and non-ED arms. ED was used for LET rise seen in 61.7% of patients (111/180) and was used if the esophagus was in the line of ablation on fluoroscopy in 38.3% of patients (69/180).
Results: Mean deviation of trailing edge of esophagus with EsoSure was 2.45 ± 0.9 cm (range 1-4.5). LET rise >1°C was significantly lower in the ED than non-ED group (3% vs 79.4%; P <.001). Mean LET rise was also lower in the ED arm (ED 0.34 ± 0.59 vs non-ED 1.66 ± 0.54; P <.001). Intraprocedural success of pulmonary vein antral isolation, was slightly improved in the ED arm than in the non-ED arm without statistical significance. AF recurrence was lower in the ED arm at 3-month, 6-month, and 1-year follow-up than in the non-ED arm. No ED-related complications were noted.
Conclusion: Mechanical displacement of the esophagus with EsoSure seems to be feasible, safe, and efficacious in enabling adequate radiofrequency energy delivery to the posterior wall of the left atrium without significant LET rise and obvious clinical signs of esophageal injury.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.hrthm.2018.04.017 | DOI Listing |
Br J Hosp Med (Lond)
January 2025
Department of Medicine, Rawalpindi Medical University, Rawalpindi, Pakistan.
The advent of once-weekly insulin icodec is a promising development in the care of individuals with diabetes. These once-weekly formulations aimed to improve patient adherence and quality of life for patients who find daily injection administration challenging. Insulin icodec has demonstrated comparable glycemic control to conventionally used daily basal insulins, such as insulin glargine and degludec, in the ONWARDS clinical trials.
View Article and Find Full Text PDFJ Endovasc Ther
January 2025
Department of Vascular Surgery, Swiss Aortic Center Bern, Inselspital, University Hospital of Bern, University of Bern, Bern, Switzerland.
Purpose: To perform a systematic review and meta-analysis of the outcomes of Anaconda fenestrated endograft for the treatment of complex abdominal aortic aneurysms (cAAA).
Material And Methods: A systematic search of all the literature reported until May 2024 was performed according to the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines. The pooled 30-day mortality rate, technical success rate, reintervention rate as well as bridging stent occlusion rate, and corresponding 95% confidence intervals (CIs) were estimated using fixed or random effect methods.
Sensors (Basel)
January 2025
School of Information Science and Technology, ShanghaiTech University, Shanghai 201210, China.
Accurately measuring the thickness of the oxide film that accumulates on nuclear fuel assemblies is critical for maintaining nuclear power plant safety. Oxide film thickness typically ranges from a few micrometers to several tens of micrometers, necessitating a high-precision measurement system. Eddy current testing (ECT) is commonly employed during poolside inspections due to its simplicity and ease of on-site implementation.
View Article and Find Full Text PDFSensors (Basel)
January 2025
School of Biomedical Engineering, Tsinghua University, Shuang Qing Road, Beijing 100084, China.
Mastoidectomy is critical in acoustic neuroma surgery, where precise planning of the bone milling area is essential for surgical navigation. The complexity of representing the irregular volumetric area and the presence of high-risk structures (e.g.
View Article and Find Full Text PDFJ Clin Med
January 2025
Gastroenterology and Hepatology, University of Iowa Hospitals and Clinics, Iowa City, IA 52242, USA.
: Endoscopic resection with lift polypectomy using submucosal injection (SI) for large non-pedunculated colorectal polyps is recommended to facilitate complete mucosal resection and decrease the risk of perforation; however, there are no studies comparing the safety and efficacy of large polypectomies with and without lift polypectomy. We aimed to evaluate the feasibility and safety of the polypectomy technique without SI compared to the routine use of SI. : We performed a single tertiary center retrospective study evaluating all consecutive large non-pedunculated colorectal polyps (≥20 mm) referred to expert endoscopists in polypectomy from 2018 through 2021.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!