Trends in vena cava filter insertions and "prophylactic" use.

J Vasc Surg Venous Lymphat Disord

Department of Population Health Science and Policy, Icahn School of Medicine at Mount Sinai, New York, NY. Electronic address:

Published: September 2018

Background: Prophylactic vena cava filter (VCF) use in patients without venous thromboembolism is common practice despite ongoing controversy. Thorough analysis of the evolution of this practice is lacking. We describe trends in VCF use and identify events associated with changes in practice.

Methods: Using the National Inpatient Sample, we conducted a retrospective observational study of U.S. adult hospitalizations from 2000 to 2014. Trends in prophylactic VCF insertion were analyzed both across the entire study population and within subgroups according to trauma status and type of concurrent surgery. Annual percentage change (APC) was calculated, and trends were analyzed using Poisson regression.

Results: Among 461,904,314 adult inpatients (median [interquartile range] age, 58.1 [38.5-74.3] years; 39.6% male), the incidence of VCF insertion increased rapidly at first (from 0.19% to 0.35%; APC, 11.2%; 95% confidence interval [CI], 10.3%-12.2%; P < .001), then at a slower rate after the publication of the Prévention du Risque d'Embolie Pulmonaire par Interruption Cave 2 (PREPIC2) trial in 2005 (from 0.35% to 0.42%; APC, 4.4%; 95% CI, 2.8%-6.0%; P < .001), and it began decreasing after the 2010 Food and Drug Administration (FDA) safety alert (from 0.42% to 0.32%; APC, -5.5%; 95% CI, -6.5% to -4.6%; P < .001). The percentage of total VCFs that had a prophylactic indication increased quickly before publication of the PREPIC2 trial (APC, 19.5%; 95% CI, 17.9%-21.0%; P < .001), increased at a slower rate after publication in 2005 (APC, 4.4%; 95% CI, 2.6%-6.2%; P < .001), and dropped after the FDA safety alert, stabilizing at 18.5% for the last 3 years (APC, -0.3%; 95% CI, -2.2% to 1.7%; P = .8). Subgroups most associated with prophylactic VCF insertion were operative trauma (odds ratio [OR], 10.9; 95% CI, 10.2-11.7), orthopedic surgery (OR, 4.7; 95% CI, 4.3-5.2), and neurosurgical procedures (OR, 3.9; 95% CI, 3.6-4.2). All groups except orthopedic surgery experienced a deceleration in prophylactic VCF growth after the publication of PREPIC2. Meanwhile, the FDA safety alert was associated with a decrease in prophylactic VCF insertions for all groups except other major surgery.

Conclusions: Whereas publication of the PREPIC2 trial led to a deceleration in prophylactic VCF insertion growth, the FDA alert had a bigger impact, leading to declining rates of prophylactic VCF use. Further investigations of prophylactic insertion of VCF in trauma, orthopedic, and neurosurgical patients are needed to determine whether current levels of use are justified.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jvsv.2018.01.018DOI Listing

Publication Analysis

Top Keywords

prophylactic vcf
24
p < 001
20
vcf insertion
16
prepic2 trial
12
fda safety
12
safety alert
12
publication prepic2
12
vcf
10
prophylactic
9
95%
9

Similar Publications

Engineering vaginal film platform for mucoadhesion and sustained drug release for HIV-1 prevention.

J Control Release

January 2025

Department of Pharmaceutical Sciences, School of Pharmacy, University of Pittsburgh, Pittsburgh, PA, USA; Magee-Womens Research Institute, Pittsburgh, PA, USA; Department of Obstetrics, Gynecology & Reproductive Sciences, School of Medicine, University of Pittsburgh, Pittsburgh, PA, USA. Electronic address:

User adherence contributes to the effectiveness of topical pre-exposure prophylactic products designed to protect against human immunodeficiency virus type 1 (HIV-1) infection. Long-acting approaches that do not require daily or coitally-dependent use could potentially improve user adherence. This study aims to develop a long-acting vaginal film to deliver an integrase inhibitor, MK-2048, for prevention of HIV-1 infection.

View Article and Find Full Text PDF

Background And Objectives: Vertebral compression fracture (VCF) is a common, but serious toxicity of spinal stereotactic body radiotherapy (SBRT). Several variables that place patients at high risk of VCF have previously been identified, including advanced Spinal Instability Neoplastic Score (SINS), a widely adopted clinical decision criterion to assess spinal instability. We examine the role of tumoral endplate (EP) disruption in the risk of VCF and attempt to incorporate it into a simple risk stratification system.

View Article and Find Full Text PDF

Objective: To determine the safety and effectiveness of vena cava filters (VCFs).

Methods: A total of 1429 participants (62.7 ± 14.

View Article and Find Full Text PDF

Objective: To determine the safety and effectiveness of vena cava filters (VCFs).

Methods: A total of 1429 participants (62.7 ± 14.

View Article and Find Full Text PDF

The use of vena cava filters (VCF) is a common procedure utilized in the prevention of pulmonary embolism (PE), yet VCFs have some significant and known complications, such as strut penetration and migration. Deep vein thrombosis (DVT) and PE remain a major cause of morbidity and mortality in the United States. It is estimated that as many as 900,000 individuals are affected by these each year with estimates suggesting that nearly 60,000-100,000 Americans die of DVT/PE each year.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!