Purpose: To evaluate the effect of two endodontic sealers on the push-out bond strength between fiber posts and root canal wall after different storage times and verify the influence of the endodontic sealers on the degree of conversion of composite cements.

Materials And Methods: A total of 180 bovine teeth were endodontically treated using two endodontic sealers, eugenol-based (Endofill, Dentsply Maillefer) or epoxy resin-based (AH Plus, Dentsply Maillefer). Subsequently, the specimens were stored in 100% relative humidity at 37°C for 24 h, 6 or 12 months. After the respective storage times, the root canals were prepared for fiber post cementation using two composite cements, RelyX U200 (3M) or Multilink Automix (Ivoclar Vivadent). The push-out test and the failure analysis were performed. Degree of conversion was analyzed using a Raman microscope, for which samples were prepared using composite cement only or composite cement plus endodontic sealer. Finally, the push-out data were subjected to statistical analysis and the degree of conversion in percent was calculated.

Results: AH Plus sealer obtained the highest push-out bond strengths at 24 h and 6 months. There was no difference between the push-out bond strengths of AH Plus and Endofill sealer at 1 year (p < 0.05). Moreover, the degree of conversion was affected by the Endofill sealer.

Conclusion: The use of a eugenol-based sealer is not recommended because it affects the push-out bond strength of fiber posts. AH Plus sealer and a post-endodontic waiting time of 24 h is recommended.

Download full-text PDF

Source
http://dx.doi.org/10.3290/j.jad.a40301DOI Listing

Publication Analysis

Top Keywords

degree conversion
20
endodontic sealers
16
push-out bond
16
bond strength
12
strength fiber
12
fiber posts
12
storage times
8
dentsply maillefer
8
composite cement
8
bond strengths
8

Similar Publications

The photocatalytic reduction of CO in water to produce fuels and chemicals is promising while challenging. However, many photocatalysts for accomplishing such challenging task usually suffer from unspecific catalytic active sites and the inefficient charge carrier's separation. Here, a site-specific single-atom Ni/TiO catalyst is reported by in situ topological transformation of Ni-Ti-EG bimetallic metal-organic frameworks.

View Article and Find Full Text PDF

Background: Mitochondria generate the adenosine triphosphate (ATP) necessary for eukaryotic cells, serving as their primary energy suppliers, and contribute to host defense by producing reactive oxygen species. In many critical illnesses, including sepsis, major trauma, and heatstroke, the vicious cycle between activated coagulation and inflammation results in tissue hypoxia-induced mitochondrial dysfunction, and impaired mitochondrial function contributes to thromboinflammation and cell death.

Methods: A computer-based online search was performed using the PubMed and Web of Science databases for published articles concerning sepsis, trauma, critical illnesses, cell death, mitochondria, inflammation, coagulopathy, and organ dysfunction.

View Article and Find Full Text PDF

Conformation Regulation of Perylene Diimide Derivatives by Lanthanide Coordination for Turn-On Fluorescence Sensing of Sarin Simulants.

Inorg Chem

January 2025

Key Laboratory of Applied Surface and Colloid Chemistry (MOE), School of Chemistry & Chemical Engineering, Shaanxi Normal University, Xi'an, Shaanxi 710062, China.

Fluorescent metal-organic frameworks (MOFs) are promising sensing materials that have received much attention in recent years, in which the organic ligand conformation changes usually lead to variations of their sensing behavior. Based on this, in the present work, perylene diimide (PDI) derivatives with excellent photochemical properties closely related to their conformation and molecule packing fashion were selected as organic linkers to detect sarin simulant diethyl chlorophosphate (DCP). By the coordination interactions with large lanthanide cations through terminal carboxylate groups from the PDI derivative, a series of one-dimensional coordination polymers, named [Ln(PDICl-2COO)(μ-O)(DMF)] (SNNU-112, Ln = Yb/Tb/Sm/Nd/Pr/Gd/Eu/Er/Ce, PDICl-2COOH = ,'-bis(4-benzoic acid)-1,2,6,7-tetrachlorohydrazone-3,4,9,10-tetracarboxylic acid diimide) were synthesized.

View Article and Find Full Text PDF

The incidence for congenital heart block is estimated as high as 1 in 15,000 live births. Up to 90% of cases of congenital heart block, in which there is no anatomical abnormalities, are attributed to maternal systemic lupus erythematous or Sjögren's disease. 50% of these mothers are asymptomatic at time of diagnosis.

View Article and Find Full Text PDF

Development of an image quality evaluation system for bedside chest X-ray images using scatter correction processing.

Radiol Phys Technol

January 2025

Department of Radiological Sciences, Graduate School of Human Health Sciences, Tokyo Metropolitan University, 7-2-10 Higashi-ogu, Arakawa, Tokyo, 116-8551, Japan.

In plain radiography, scattered X-ray correction processing (Virtual Grid: VG) is used to estimate and correct scattered rays in images. We developed an objective evaluation system for bedside chest X-ray images using VG and investigated its usefulness. First, we trained the blind/referenceless image spatial quality evaluator (BRISQUE) on 200 images obtained by portable chest radiography.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!