Purpose: The study aimed to develop a motion capture system that can track, visualize, and analyze the entire performance of self-injection with the auto-injector.

Methods: Each of nine healthy subjects and 29 rheumatoid arthritic (RA) patients with different degrees of hand disability performed two simulated injections into an injection pad while six degrees of freedom (DOF) motions of the auto-injector and the injection pad were captured. We quantitatively measured the performance of the injection by calculating needle displacement from the motion trajectories. The max, mean, and SD of needle displacement were analyzed. Assessments of device acceptance and usability were evaluated by a survey questionnaire and independent observations of compliance with the device instruction for use (IFU).

Results: A total of 80 simulated injections were performed. Our results showed a similar level of performance among all the subjects with slightly larger, but not statistically significant, needle displacement in the RA group. In particular, no significant effects regarding previous experience in self-injection, grip method, pain in hand, and Cochin score in the RA group were found to have an impact on the mean needle displacement. Moreover, the analysis of needle displacement for different durations of injections indicated that most of the subjects reached their personal maximum displacement in 15 seconds and remained steady or exhibited a small amount of increase from 15 to 60 seconds. Device acceptance was high for most of the questions (ie, >4; >80%) based on a 0-5-point scale or percentage of acceptance. The overall compliance with the device IFU was high for the first injection (96.05%) and reached 98.02% for the second injection.

Conclusion: We demonstrated the feasibility of tracking the motions of injection to measure the performance of simulated self-injection. The comparisons of needle displacement showed that even RA patients with severe hand disability could properly perform self-injection with this auto-injector at a similar level with the healthy subjects. Finally, the observed high device acceptance and compliance with device IFU suggest that the system is convenient and easy to use.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5898887PMC
http://dx.doi.org/10.2147/PPA.S160394DOI Listing

Publication Analysis

Top Keywords

needle displacement
24
acceptance compliance
12
device acceptance
12
compliance device
12
rheumatoid arthritic
8
motion capture
8
capture system
8
healthy subjects
8
hand disability
8
simulated injections
8

Similar Publications

Background And Objectives: Härtel triangle provides surface landmarks for locating the foramen ovale (FO) when performing trigeminal nerve percutaneous procedures. Although widely adopted in clinical practice, there is no report that these landmarks have ever been formally validated through modern imaging techniques. Here we aim to validate Härtel anatomical landmarks using computed tomography scans and propose technical considerations for percutaneous trigeminal procedures.

View Article and Find Full Text PDF

Arthrocentesis of Temporomandibular Joints-A Clinical Comparative Study.

Life (Basel)

December 2024

Department of Cranio-Maxillofacial Surgery, Oral Surgery and Implantology, Medical University of Warsaw, 02-005 Warsaw, Poland.

The objective of this study was to compare single-needle arthrocentesis with the conventional two-needle arthrocentesis, as well as the additional intracapsular injection of hyaluronic acid or platelet-rich fibrin. A total of 96 patients with established osteoarthritis (OA) ( = 48) or with internal de-arrangement (DD) ( = 48) were assigned single-needle arthrocentesis with distension of the joint or conventional two-needle arthrocentesis with or without intracapsular injection of the medication (hyaluronic acid (HA) or platelet-rich plasma (PRP)) performed every month over a period of 6 months. The maximum mouth opening and pain, as measured by the visual analog scale (VAS), were compared.

View Article and Find Full Text PDF

Introduction Spinal fusion surgery with pedicle screws is commonly performed to stabilize the spine of osteoporotic patients. However, securing a strong screw fixation in osteoporotic bone presents significant challenges due to the reduced bone density. This study aimed to compare the biomechanical performance in an osteoporotic bone model of pedicle screws inserted using two different techniques, the Jamshidi needle technique and the pedicle probe technique, as well as the influence of tapping on both these techniques.

View Article and Find Full Text PDF

Objective: To explore weight-bearing stability of Pilon fracture fixed by external fixator.

Methods: Six ankle bone models (right side) and 4 pairs (8 ankle cadaver specimens) were selected. Pilon fracture model was prepared by using the preset osteotomy line based on Ruedi Allgower Pilon fracture type.

View Article and Find Full Text PDF

Hirayama disease (HD) is a rare disorder characterized by insidious asymmetric neurogenic atrophy primarily involving the upper extremities. HD most commonly affects adolescent males and has a favorable prognosis for arrest of progression. Electrodiagnostic (EDX) studies show chronic denervation changes in the distal upper extremity muscles.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!