We have investigated limited angle transmission tomography to estimate speed of sound (SOS) distributions for breast cancer detection. That requires both accurate delineations of major tissues, in this case by segmentation of prior B-mode images, and calibration of the relative positions of the opposed transducers. Experimental sensitivity evaluation of the reconstructions with respect to segmentation and calibration errors is difficult with our current system. Therefore, parametric studies of SOS errors in our bent-ray reconstructions were simulated. They included mis-segmentation of an object of interest or a nearby object, and miscalibration of relative transducer positions in 3D. Close correspondence of reconstruction accuracy was verified in the simplest case, a cylindrical object in homogeneous background with induced segmentation and calibration inaccuracies. Simulated mis-segmentation in object size and lateral location produced maximum SOS errors of 6.3% within 10 mm diameter change and 9.1% within 5 mm shift, respectively. Modest errors in assumed transducer separation produced the maximum SOS error from miscalibrations (57.3% within 5 mm shift), still, correction of this type of error can easily be achieved in the clinic. This study should aid in designing adequate transducer mounts and calibration procedures, and in specification of B-mode image quality and segmentation algorithms for limited angle transmission tomography relying on ray tracing algorithms.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ultras.2018.03.016 | DOI Listing |
Investigating muscle architecture in static and dynamic conditions is essential to understand muscle function and muscle adaptations. Muscle architecture analysis, primarily through extended field-of-view ultrasound imaging, offers high reliability at rest but faces limitations during dynamic conditions. Traditional methods often involve "best fitting" straight lines to track muscle fascicles, leading to possible errors, especially with longer fascicles or those with nonlinear paths.
View Article and Find Full Text PDFExp Physiol
January 2025
Department of Clinical Medicine, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark.
There is limited knowledge on diffusing capacity in scoliosis patients. It remains to be determined if impaired pulmonary diffusing capacity is mostly influenced by reduced alveolar-capillary membrane diffusing capacity (D), reduced pulmonary capillary blood volume (V) or both. This study aims to report findings from dual test gas pulmonary diffusing capacity for carbon monoxide and nitric oxide (D) with quantification of pulmonary diffusing capacity for carbon monoxide corrected for haemoglobin with a five s breath-hold (D) and nitric oxide with a five s breath-hold (D), D and V.
View Article and Find Full Text PDFCurr Drug Deliv
January 2025
Department of Pharmaceutical Sciences, School of Pharmacy, Shanghai University of Traditional Chinese Medicine, Shanghai 201203, China.
Background: Hot-melt Pressure-sensitive Adhesives (HMPSA) are eco-friendly pressuresensitive adhesives, with the potential of being used as substrates for transdermal patches. However, due to the low hydrophilicity of HMPSA, the application is limited in the field of Traditional Chinese Medicine (TCM) plasters.
Methods: Three modified HMPSA were prepared with acrylic resin EPO, acrylic resin RL100, and Polyvinylpyrrolidone (PVP) as the modifying materials.
Biomed Opt Express
January 2025
Department of Biomedical Engineering, University of Illinois Chicago, Chicago, IL 60607, USA.
The choroid, a critical vascular layer beneath the retina, is essential for maintaining retinal function and monitoring chorioretinal disorders. Existing imaging methods, such as indocyanine green angiography (ICGA) and optical coherence tomography (OCT), face significant limitations, including contrast agent requirements, restricted field of view (FOV), and high costs, limiting accessibility. To address these challenges, we developed a nonmydriatic, contrast agent-free fundus camera utilizing transcranial near-infrared (NIR) illumination.
View Article and Find Full Text PDFMagn Reson Med
January 2025
Department of Radiology, Stanford University, Stanford, California, USA.
Purpose: To provide a fast quantitative imaging approach for a 0.55T scanner, where signal-to-noise ratio is limited by the field strength and k-space sampling speed is limited by a lower specification gradient system.
Methods: We adapted the three-dimensional spiral projection imaging MR fingerprinting approach to 0.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!