Aims: This study assessed the contemporary occurrence of cardiac device infections (CDIs) following implantation in French hospitals and estimated associated costs.

Methods And Results: A retrospective analysis was conducted on the French National Hospital Database (PMSI). Patients with a record of de novo cardiac implantable electronic device (CIED) implantation or replacement interventions in France in 2012 were identified and followed until the end of 2015. Cardiac device infections (CDIs) were identified based on coding using the French classification for procedures [Classification Commune des Actes Médicaux (CCAM)] and International Classification of Diseases (ICD-10). Associated costs were estimated based on direct costs from the perspective of the French social security system. In total 78 267 CIED patients (72% de novo implants) were identified (15% defibrillators; 84% pacemakers). The 36-month infection rate associated with de novo defibrillator-only implants, as well as for cardiac resynchronisation therapy - defibrillators (CRT-Ds) was 1.6%. The CDI risk was 2.9% and 3.9% for replacement ICDs and CRT-Ds. Infection rates were lower for de novo single-chamber pacemaker (SCP)/dual-chamber pacemaker (DCP) (0.5%) and cardiac resynchronisation therapy - pacemaker (CRT-P) implants (1.0%), while for replacement procedures the risk increased to 1.4% (SCP/DCP) and 1.3% (CRT-P). Mean infection-related costs over 24 months were €20 623 and €23 234 for CDIs associated with replacement and de novo procedures, and overall costs were not significantly different between pacemaker and defibrillator patients.

Conclusion: Cardiac device infections in France are associated with substantial costs, when considering inpatient hospitalizations. Strategies to minimize the rate of CIED infection should be a priority for health care providers and payers.

Download full-text PDF

Source
http://dx.doi.org/10.1093/europace/eux387DOI Listing

Publication Analysis

Top Keywords

cardiac device
12
device infections
12
associated costs
8
implantable electronic
8
electronic device
8
infections cdis
8
cardiac resynchronisation
8
resynchronisation therapy
8
costs
6
cardiac
6

Similar Publications

Vertebral collapse (VC) following osteoporotic vertebral compression fracture (OVCF) often requires aggressive treatment, necessitating an accurate prediction for early intervention. This study aimed to develop a predictive model leveraging deep neural networks to predict VC progression after OVCF using magnetic resonance imaging (MRI) and clinical data. Among 245 enrolled patients with acute OVCF, data from 200 patients were used for the development dataset, and data from 45 patients were used for the test dataset.

View Article and Find Full Text PDF

Prognostic role of aetiological agent vs. clinical pattern in candidates to lead extraction for cardiac implantable electronic device infections.

Sci Rep

December 2024

Department of Medical and Surgical Sciences, Institute of Cardiology, University of Bologna, Policlinico S.Orsola-Malpighi, via Massarenti 9, Bologna, 40138, Italy.

Cardiac implantable electronic devices infections (CIEDI) are associated with poor survival despite the improvement in transvenous lead extraction (TLE). Aetiology and systemic involvement are driving factors of clinical outcomes. The aim of this study was to explore their contribute on overall mortality.

View Article and Find Full Text PDF

BAY 2413555 is a novel selective and reversible positive allosteric modulator of the type 2 muscarinic acetylcholine (M2) receptor, aimed at enhancing parasympathetic signaling and restoring cardiac autonomic balance for the treatment of heart failure (HF). This study tested the safety, tolerability and pharmacokinetics of this novel therapeutic option. REMOTE-HF was a multicenter, double-blind, randomized, placebo-controlled, phase Ib dose-titration study with two active arms.

View Article and Find Full Text PDF

Mid-infrared photoacoustic microscopy can capture biochemical information without staining. However, the long mid-infrared optical wavelengths make the spatial resolution of photoacoustic microscopy significantly poorer than that of conventional confocal fluorescence microscopy. Here, we demonstrate an explainable deep learning-based unsupervised inter-domain transformation of low-resolution unlabeled mid-infrared photoacoustic microscopy images into confocal-like virtually fluorescence-stained high-resolution images.

View Article and Find Full Text PDF

Exciton Transport in Perovskite Materials.

Adv Mater

December 2024

Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA.

Halide perovskites have emerged as promising materials for a wide variety of optoelectronic applications, including solar cells, light-emitting devices, photodetectors, and quantum information applications. In addition to their desirable optical and electronic properties, halide perovskites provide tremendous synthetic flexibility through variation of not only their chemical composition but also their structure and morphology. At the heart of their use in optoelectronic technologies is the interaction of light with electronic excitations in the form of excitons.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!