Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Analyses of drugs and poisons in tissue samples are essential in forensic toxicology and pharmacology. However, current procedures for tissue analysis are laborious and time-consuming. Therefore, we assessed the utility of a newly devised probe electrospray ionization (PESI) technique with tandem mass spectrometry (MS/MS) for easy, ultra-rapid drug detection in human tissue samples. Using this system, typical pretreatment procedures, such as solid-phase extraction, liquid-liquid extraction, deproteinization, or homogenization, can be avoided. Briefly, a tissue sample of 1-2 mm was supplemented with a solution of ethanol and 10 mmol/L ammonium formate, and measurements were obtained. We demonstrated the successful application of this method in a forensic case by detecting an opioid analgesic, MT-45, in all tissue samples (liver, kidney, lung, brain, and heart). We also detected oxidized metabolites of MT-45 in the liver. Since the analysis required only 0.5 minutes per sample, PESI-MS/MS is an ultra-rapid detection method. Furthermore, for a quantitative approach, the total analysis time for the combination of PESI-MS/MS with the quick, easy, cheap, effective, rugged, and safe (QuEChERS) extraction method (from instrument start-up to extraction and PESI-analysis) was within 8 minutes. MT-45 concentrations obtained by QuEChERS-PESI-MS/MS and liquid chromatography (LC) -MS/MS were similar for all tissue samples. PESI-MS/MS cannot be used to separate isobars/isomers (ie, compounds with the same m/z value), similar to other direct introduction techniques. Further studies are needed to validate the quantitation method. However, our results indicate that PESI-MS/MS is a potentially easy and rapid technique for the analysis of drugs and poisons in human tissue samples.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/dta.2390 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!