Measurements of the dose equivalent at different distances from the isocenter of the proton therapy center at iThemba LABS were previously performed with a tissue-equivalent proportional counter (TEPC). These measurements showed that the scattered radiation levels were one or two orders of magnitude higher in comparison to other passive scattering delivery systems. In order to reduce these radiation levels, additional shielding was installed shortly after the measurements were done. Therefore, the aim of this work is to quantify and assess the reduction of the secondary doses delivered in the proton therapy room at iThemba LABS after the installation of the additional shielding. This has been performed by measuring microdosimetric spectra with a TEPC at 11 locations around the isocenter when a clinical modulated beam of 200 MeV proton was impinging onto a water phantom placed at the isocenter.

Download full-text PDF

Source
http://dx.doi.org/10.1093/rpd/ncy056DOI Listing

Publication Analysis

Top Keywords

proton therapy
12
ithemba labs
12
therapy room
8
room ithemba
8
tissue-equivalent proportional
8
proportional counter
8
radiation levels
8
additional shielding
8
microdosimetric measurement
4
measurement secondary
4

Similar Publications

Background: Most older patients with atrial fibrillation (AF) have comorbidities. However, it is unclear whether specific comorbidity patterns are associated with adverse outcomes. We identified comorbidity patterns and their association with mortality in multimorbid older AF patients with different multidimensional frailty.

View Article and Find Full Text PDF

Background: For early-stage lung cancer, sublobar resection (SLR) is an alternative to lobectomy, which is the standard treatment. Recently, proton therapy (PT) is being increasingly used, even in patients with operable lung cancer, as an attractive alternative to conventional radiation therapy. Thus, we performed propensity score matching (PSM) to compare the outcomes of SLR and PT in patients with early-stage non-small cell lung cancer (NSCLC).

View Article and Find Full Text PDF

Gastroesophageal reflux is a common physiologic event in infants in which gastric contents pass from the stomach into the esophagus. Gastroesophageal reflux may be asymptomatic or cause regurgitation or "spit up." This occurs daily in approximately 40% of infants.

View Article and Find Full Text PDF

Recent investigations into radiation-induced side effects have focused on understanding the physiopathological consequences of irradiation on late-responding tissues like the spinal cord, which can lead to chronic progressive myelopathy. Proton therapy, an advanced radiation treatment, aims to minimize damage to healthy tissues through precise dose deposition. However, challenges remain, particularly regarding the variation in dose distribution, characterized by maximum deposition at the end of the proton range, known as the distal fall-off of a spread-out Bragg peak.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!