Objective: Motion artifact can reduce the diagnostic accuracy of coronary CT angiography (CCTA) for coronary artery disease (CAD). The purpose of this study was to compare the diagnostic performance of an algorithm dedicated to correcting coronary motion artifact with the performance of standard reconstruction methods in a prospective international multicenter study.

Subjects And Methods: Patients referred for clinically indicated invasive coronary angiography (ICA) for suspected CAD prospectively underwent an investigational CCTA examination free from heart rate-lowering medications before they underwent ICA. Blinded core laboratory interpretations of motion-corrected and standard reconstructions for obstructive CAD (≥ 50% stenosis) were compared with ICA findings. Segments unevaluable owing to artifact were considered obstructive. The primary endpoint was per-subject diagnostic accuracy of the intracycle motion correction algorithm for obstructive CAD found at ICA.

Results: Among 230 patients who underwent CCTA with the motion correction algorithm and standard reconstruction, 92 (40.0%) had obstructive CAD on the basis of ICA findings. At a mean heart rate of 68.0 ± 11.7 beats/min, the motion correction algorithm reduced the number of nondiagnostic scans compared with standard reconstruction (20.4% vs 34.8%; p < 0.001). Diagnostic accuracy for obstructive CAD with the motion correction algorithm (62%; 95% CI, 56-68%) was not significantly different from that of standard reconstruction on a per-subject basis (59%; 95% CI, 53-66%; p = 0.28) but was superior on a per-vessel basis: 77% (95% CI, 74-80%) versus 72% (95% CI, 69-75%) (p = 0.02). The motion correction algorithm was superior in subgroups of patients with severely obstructive (≥ 70%) stenosis, heart rate ≥ 70 beats/min, and vessels in the atrioventricular groove.

Conclusion: The motion correction algorithm studied reduces artifacts and improves diagnostic performance for obstructive CAD on a per-vessel basis and in selected subgroups on a per-subject basis.

Download full-text PDF

Source
http://dx.doi.org/10.2214/AJR.17.18670DOI Listing

Publication Analysis

Top Keywords

motion correction
28
correction algorithm
28
obstructive cad
20
diagnostic accuracy
16
standard reconstruction
16
diagnostic performance
12
coronary angiography
12
algorithm
9
motion
9
intracycle motion
8

Similar Publications

The proper development of balance is essential in the acquisition of a correct physical condition, as well as in the evolutionary follow-up at early ages, and its periodic evaluation is very relevant in the educational environment. : The objective of this research was to design an accessible web application for static and dynamic balance assessment, based on a force platform and motion analysis software. : The Single leg balance test (SLB), Tandem balance test (TBT), and Y balance test (YBT) were performed on a sample of 75 children aged 6 to 9 years.

View Article and Find Full Text PDF

Introduction: Total knee arthroplasty (TKA) in severe varus deformity still remains a challenge. Alternative alignment TKA aims to improve outcomes and satisfaction. The purpose of this study is to report on the outcomes of a functionally aligned TKA in severe varus deformity.

View Article and Find Full Text PDF

Background: Congenital radioulnar synostosis (CRUS) is a rare upper limb deformity characterized by impaired rotational movement of the forearm. Rotational osteotomy is a commonly employed surgical procedure for treatment. This study aimed to analyze its surgical efficacy in treating CRUS in children.

View Article and Find Full Text PDF

Purpose: To evaluate the image quality of an ultrafast cone-beam computed tomography (CBCT) system-Varian HyperSight.

Methods And Materials: In this evaluation, 5 studies were performed to assess the image quality of HyperSight CBCT. First, a HyperSight CBCT image quality evaluation was performed and compared with Siemens simulation-CT and Varian TrueBeam CBCT.

View Article and Find Full Text PDF

Background: There is a relative paucity of studies examining how the superior capsule reconstruction (SCR) may alter the kinematics of the glenohumeral joint capsule itself, specifically with respect to rotation and translation in the anterior-posterior and superior-inferior planes. This then raises the possibility that the SCR may be having unintended consequences on glenohumeral kinematics. The purpose of this study was to quantify the glenohumeral joint kinematics following Fascia Lata SCR (FL-SCR).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!