Cone synapses in mammalian retinal rod bipolar cells.

J Comp Neurol

Department of Ophthalmology, Baylor College of Medicine, Houston, Texas, 77030.

Published: August 2018

Some mammalian rod bipolar cells (RBCs) can receive excitatory chemical synaptic inputs from both rods and cones (DBC ), but anatomical evidence for mammalian cone-RBC contacts has been sparse. We examined anatomical cone-RBC contacts using neurobiotin (NB) to visualize individual mouse cones and standard immuno-markers to identify RBCs, cone pedicles and synapses in mouse and baboon retinas. Peanut agglutinin (PNA) stained the basal membrane of all cone pedicles, and mouse cones were positive for red/green (R/G)-opsin, whereas baboon cones were positive for calbindin D-28k. All synapses in the outer plexiform layer were labeled for synaptic vesicle protein 2 (SV2) and PSD (postsynaptic density)-95, and those that coincided with PNA resided closest to bipolar cell somas. Cone-RBC synaptic contacts were identified by: (a) RBC dendrites deeply invaginating into the center of cone pedicles (invaginating synapses), (b) RBC dendritic spines intruding into the surface of cone pedicles (superficial synapses), and (c) PKCα immunoreactivity coinciding with synaptic marker SV2, PSD-95, mGluR6, G protein beta 5 or PNA at cone pedicles. One RBC could form 0-1 invaginating and 1-3 superficial contacts with cones. 20.7% and 38.9% of mouse RBCs contacted cones in the peripheral and central retina (p < .05, n = 14 samples), respectively, while 34.4% (peripheral) and 48.5% (central) of cones contacted RBCs (p > .05). In baboon retinas (n = 4 samples), cone-RBC contacts involved 12.2% of RBCs (n = 416 cells) and 22.5% of cones (n = 225 cells). This suggests that rod and cone signals in the ON pathway are integrated in some RBCs before reaching AII amacrine cells.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6031453PMC
http://dx.doi.org/10.1002/cne.24456DOI Listing

Publication Analysis

Top Keywords

cone pedicles
20
cone-rbc contacts
12
rod bipolar
8
bipolar cells
8
mouse cones
8
baboon retinas
8
cones positive
8
cone
7
cones
7
cells
5

Similar Publications

Median mandibular cyst is defined as an odontogenic cyst in a rare midline location. In spite of this definition, there have been two reports of a peculiar lesion, so-called "ciliated" median mandibular cyst associated with vital teeth, the origin of which cannot be explained in terms of odontogenic epithelium multipotentiality. We describe a thorough profile of an additional example.

View Article and Find Full Text PDF

Background: Laparoscopic anatomical liver resection has become more challenging because some subsegmental Glissonean pedicles are hard to dissect. Here, we introduce how to dissect every (sub) segmental Glissonean pedicle from the first porta hepatis and perform standardized (sub) segmentectomy [from segment 1 (S1) to S8].

Aim: To summarize our methods of laparoscopic anatomical segmental and subsegmental liver resection.

View Article and Find Full Text PDF

An 85-year-old white male presented with a basal cell carcinoma on the right cheek, treated with Mohs micrographic surgery, resulting in a 5.8 x 3.2 cm defect across multiple facial subunits.

View Article and Find Full Text PDF

Comparison of different imaging devices and navigation systems for cervical pedicle screw placement: an experimental study on screw accuracy, screw placement time and radiation dose.

Sci Rep

November 2024

Research group Medical Imaging and Navigation in Trauma and Orthopedic Surgery (MINTOS), Department of Orthopedics and Trauma Surgery, BG Klinik Ludwigshafen, Ludwig- Guttmann-Str. 13, 67071, Ludwigshafen, Germany.

Cervical pedicle screws (CPS) provide biomechanically superior fixation compared to other techniques but are technically more demanding. Navigated CPS placement has been increasingly reported as a safe and accurate technique, yet there are few studies comparing different combinations of imaging and navigation systems under comparable conditions. With this study, we aimed to compare different imaging and navigation systems for CPS placement in terms of accuracy, screw placement time and applied radiation dose.

View Article and Find Full Text PDF

Innovation in image-guided procedures has been driven by advances in robotic Cone Beam Computed Tomography (CBCT) systems. A fundamental challenge for CBCT imaging is metal artifacts arising from surgical tools and implanted hardware. Here, we outline how two universal non-circular imaging orbits, optimized for metal artifact reduction, can be implemented in real-time on clinical robotic CBCT systems.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!