Purpose: Myocardial bridges (MB) have traditionally been considered a benign condition, but recent studies have demonstrated that the clinical complications can be dangerous. The transluminal attenuation gradient (TAG) obtained from coronary computed tomography angiography (CCTA) data (Retrospective ECG-triggered method) has been used in detecting significant stenosis in coronary artery caused by atherosclerosis. Contrast opacification difference (COD) was the parameters calculated as the change between attenuation of mural artery and the median attenuation of presumptive vessel segment; it was evaluated along with TAG (TAGs) and MB length for predicting MB with systolic compression (MB-SC) in patients diagnosed as MB in left anterior descending coronary artery (LAD) by CCTA or invasive coronary angiograph (ICA).

Methods: A total of 107 MB patients were divided into three groups based on systolic compression (SC), including: Group 1 (MB without SC); Group 2 (MB with mild SC); and Group 3 (MB with significant SC). ANOVA and Kruskal-Wallis analysis indicated TAGs showed the most significant differences for MB identification.

Results: This study revealed that TAGs decreasing and COD increasing were dominated in MB with significant SC.

Conclusions: COD had a higher sensitivity and a higher negative predictive value for detecting MB with significant SC than TAGs.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00276-018-2014-4DOI Listing

Publication Analysis

Top Keywords

systolic compression
12
contrast opacification
8
opacification difference
8
mural artery
8
transluminal attenuation
8
attenuation gradient
8
coronary computed
8
computed tomography
8
tomography angiography
8
coronary artery
8

Similar Publications

Controlling the stability of monodisperse phospholipid-coated microbubbles by tuning their buckling pressure.

J Colloid Interface Sci

January 2025

BIOS/Lab on a Chip Group, Max Planck Center Twente for Complex Fluid Dynamics, MESA+ Institute for Nanotechnology, Faculty of Electrical Engineering, Mathematics and Computer Science, University of Twente, P.O. Box 217, Enschede, 7500 AE, the Netherlands. Electronic address:

Hypothesis: Monodisperse phospholipid-coated microbubbles, with a size and resonance frequency tuned to the ultrasound driving frequency, have strong potential to enhance sensitivity, efficiency, and control in emerging diagnostic and therapeutic applications involving bubbles and ultrasound. A key requirement is that they retain their gas volume and shell material during physiologic pressure changes and withstand the overpressure during intravenous injection. The shell typically comprises a mixture of a phospholipid (e.

View Article and Find Full Text PDF

Posterior reversible encephalopathy syndrome (PRES) is a clinical manifestation of various underlying causes, characterized by the combination of clinical and imaging findings associated with the posterior cerebral areas and relating to arterial hypertension and endothelial dysfunction. No association was made so far between PRES and McCune-Albright syndrome (MAS), a rare genetic disorder resulting in fibrous dysplasia. A 33-year-old female with MAS was presented to the emergency department of the 417 Army Share Fund Hospital in Athens (Greece) after seizure activity with two episodes of ocular upward deviation and transient facial palsy, each lasting a few minutes, followed by a postictal phase.

View Article and Find Full Text PDF

Background: Pulmonary hypertension caused by extrinsic pulmonary vascular compression secondary to mediastinal neuroendocrine tumours is a very rare condition, posing a diagnostic challenge. There is no clear consensus regarding the best treatment strategy due to the lack of clinical data, leading to poor prognoses for these patients.

Case Summary: We present the case of a 38-year-old man hospitalized with signs of pulmonary hypertension and acute heart failure.

View Article and Find Full Text PDF

A young man presented with complaints of angina on exertion and dyspnoea on exertion for the last 3 months. On evaluation, he was found to have a cystic mass in the left ventricle with severe left ventricular systolic dysfunction. A cardiac MRI revealed a multiloculated mass in the left ventricle with multiple septa with internal enhancement and CT coronary angiography revealed compression of a coronary artery by the cystic mass.

View Article and Find Full Text PDF

Image reconstruction impacts haemodynamic parameters derived from 4D flow magnetic resonance imaging with compressed sensing.

Eur Heart J Imaging Methods Pract

October 2024

Clinical Physiology, Department of Clinical Sciences Lund, Lund University, Lund 221 00, Sweden.

Aims: 4D blood flow measurements by cardiac magnetic resonance imaging (CMR) can be used to simplify blood flow assessment. Compressed sensing (CS) can provide better flow measurements than conventional parallel imaging (PI), but clinical validation is needed. This study aimed to validate stroke volume (SV) measurements by 4D-CS in healthy volunteers and patients while also investigating the influence of the CS image reconstruction parameter on haemodynamic parameters.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!