Background: The potential for a fibrin sealant patch to reduce the risk of postoperative pancreatic fistula (POPF) remains uncertain. The aim of this study was to evaluate whether a fibrin sealant patch is able to reduce POPF in patients undergoing pancreatoduodenectomy with pancreatojejunostomy.
Methods: In this multicentre trial, patients undergoing pancreatoduodenectomy were randomized to receive either a fibrin patch (patch group) or no patch (control group), and stratified by gland texture, pancreatic duct size and neoadjuvant treatment. The primary endpoint was POPF. Secondary endpoints included complications, drain-related factors and duration of hospital stay. Risk factors for POPF were identified by logistic regression analysis.
Results: A total of 142 patients were enrolled. Forty-five of 71 patients (63 per cent) in the patch group and 40 of 71 (56 per cent) in the control group developed biochemical leakage or POPF (P = 0·392). Fistulas were classified as grade B or C in 16 (23 per cent) and ten (14 per cent) patients respectively (P = 0·277). There were no differences in postoperative complications (54 patients in patch group and 50 in control group; P = 0·839), drain amylase concentration (P = 0·494), time until drain removal (mean(s.d.) 11·6(1·0) versus 13·3(1·3) days; P = 0·613), fistula closure (17·6(2·2) versus 16·5(2·1) days; P = 0·740) and duration of hospital stay (22·1(2·2) versus 18·2(0·9) days; P = 0·810) between the two groups. Multivariable logistic regression analysis confirmed that obesity (odds ratio (OR) 5·28, 95 per cent c.i. 1·20 to 23·18; P = 0·027), soft gland texture (OR 9·86, 3·41 to 28·54; P < 0·001) and a small duct (OR 5·50, 1·84 to 16·44; P = 0·002) were significant risk factors for POPF. A patch did not reduce the incidence of POPF in patients at higher risk.
Conclusion: The use of a fibrin sealant patch did not reduce the occurrence of POPF and complications after pancreatoduodenectomy with pancreatojejunostomy. Registration number: 2013-000639-29 (EudraCT register).
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5989938 | PMC |
http://dx.doi.org/10.1002/bjs.10840 | DOI Listing |
ACS Appl Bio Mater
January 2025
Department of Materials Engineering, Isfahan University of Technology, Isfahan 84156-83111, Iran.
Burns carry a large surface area, varying in shapes and depths, and an elevated risk of infection. Regardless of the underlying etiology, burns pose significant medical challenges and a high mortality rate. Given the limitations of current therapies, tissue-engineering-based treatments for burns are inevitable.
View Article and Find Full Text PDFInt J Breast Cancer
December 2024
College of Medicine, King Faisal University, Al-Ahsa City, Eastern Province, Saudi Arabia.
This study is aimed at evaluating the effectiveness of TachoSil in controlling lymphatic leakage in breast cancer patients undergoing axillary dissection. By examining its ability to reduce postsurgical lymphatic drainage, the study will assess its impact on complications like seroma formation, recovery time, and overall patient outcomes, including quality of life and reduced healthcare costs. Breast cancer patients treated in the Department of Surgical Oncology at King Abdulaziz Medical City were enrolled to receive either TachoSil or undergo drain placement after axillary dissection.
View Article and Find Full Text PDFCells
December 2024
Department of Biochemistry, College of Medicine, Ewha Womans University, Seoul 07804, Republic of Korea.
In general, the nerve cells of the peripheral nervous system regenerate normally within a certain period after the physical damage of their axon. However, when peripheral nerves are transected by trauma or tissue extraction for cancer treatment, spontaneous nerve regeneration cannot occur. Therefore, it is necessary to perform microsurgery to connect the transected nerve directly or insert a nerve conduit to connect it.
View Article and Find Full Text PDFJ Indian Soc Periodontol
December 2024
Department of Periodontology, K. M. Shah Dental College and Hospital, Sumandeep Vidyapeeth, Vadodara, Gujarat, India.
CRSLS
January 2025
Northwell Health-Lenox Hill Hospital, New York, NY. (Drs. Chu, Alden, and Seckin).
Introduction: There is a risk of iatrogenic vascular injuries during robotic-assisted laparoscopic excision of diaphragmatic endometriosis. Although studies are limited, the first reported case of a suprahepatic inferior vena cava (IVC) injury during robotic diaphragmatic endometriosis excision was successfully treated using a fibrin sealant patch, preventing exsanguination and conversion to laparotomy.
Case Description: A 36-year-old female with a history of recurrent catamenial pneumothorax and two prior video-assisted thoracoscopic surgeries to treat diaphragmatic endometriosis presented to our clinic with right-sided shoulder pain and a chest tube in place.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!