With over 150,000 implantations performed over the world, transcatheter aortic valve replacement (TAVR) has become a surgical technique, which largely competes with open surgery valve replacement for an increasing number of patients. The success of the procedure favors the research toward synthetic valve leaflet materials as an alternative to biological tissues, whose durability remains unknown. In particular, fibrous constructions have recently proven to be durable in vivo over a 6-month period of time in animal sheep models. Exaggerated fibrotic tissue formation remains, however, a critical issue to be addressed. This work investigates the design of a composite fibrous construction combining a woven polyethylene terephthalate (PET) layer and a non-woven PET mat, which are expected to provide, respectively, strength and appropriate topography toward limited fibrotic tissue ingrowth. For this purpose, a specific equipment has been developed to produce non-woven PET mats made from fibers with small diameter. These mats were assembled with woven PET substrates using various assembling techniques in order to obtain hybrid fibrous constructions. The physical and mechanical properties of the obtained materials were assessed and valve samples were manufactured to be tested in vitro for hydrodynamic performances. The results show that the composite fibrous construction is characterized by properties suitable for the valve leaflet function, but the durability of the assembling is however limited under accelerated cyclic loading.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1515/bmt-2017-0226 | DOI Listing |
Catheter Cardiovasc Interv
January 2025
IRCCS Pol. S. Donato, Milan, Italy.
Transfemoral transcatheter aortic valve Replacement (TAVR) has become the standard therapy for patients with severe aortic stenosis in patients over 75 years old in Europe or 65 years old in the United States, regardless of the surgical risk. Furthermore, iterations of existing transcatheter aortic valves (TAVs), as well as devices with novel concepts, have provided substantial improvements with respect to the limitations of previous-generation devices. Hence, treatment of a broader spectrum of patients has become feasible, and a sophisticated selection of the appropriate TAV tailored to patients' anatomy and comorbidities is now possible.
View Article and Find Full Text PDFMultimed Man Cardiothorac Surg
January 2025
Department of Cardiothoracic Surgery, Faculty of Medicine, Mansoura University Mansoura, Egypt.
The Ross procedure continues to be the best procedure to address unrepairable aortic valve pathology, especially in young adults. The Achilles heel of this procedure has been aortic root dilation and the potential need for a reoperation that may be associated with slightly increased risks in addition to the need for intervention on the pulmonary outflow tract. Modifying the Ross procedure by autograft inclusion inside a Dacron graft seems to have the potential advantage of stabilizing the autograft diameter, which may be associated with improved durability and decrease the need for future intervention.
View Article and Find Full Text PDFJ Cardiovasc Dev Dis
January 2025
Cardiovascular Center, Cathay General Hospital, Taipei 106, Taiwan.
Background: A staging system based on cardiac damage for severe aortic stenosis (AS) has been validated for prognosis prediction following transcatheter aortic valve replacement (TAVR). Our study aims to investigate whether TAVR can lead to changes in cardiac damage shortly after the procedure and how these changes impact prognosis.
Method: Patients in this retrospective cohort study were classified into five stages (0-4) before TAVR based on the echocardiographic findings of cardiac damage.
J Cardiovasc Dev Dis
December 2024
Department of Cardiothoracic and Vascular Surgery, Montefiore Medical Center, Bronx, NY 10467, USA.
The use of extracorporeal membrane oxygenation (ECMO) has emerged as a rescue intervention for hemodynamically unstable patients and prophylactic intraprocedural hemodynamic support in the cardiac catheterization laboratory. The prompt initiation of ECMO provides immediate hemodynamic support and allows for the completion of bridging and/or life-saving interventions. However, there are no clinical practice guidelines for the use of extracorporeal support in this area.
View Article and Find Full Text PDFJ Cardiovasc Dev Dis
December 2024
Interventional Cardiology Unit, IRCCS San Raffaele Scientific Institute, 20132 Milan, Italy.
Transcatheter aortic valve replacement (TAVR) in patients with severe aortic stenosis and raphe-type bicuspid aortic valve (BAV) is still associated with poor outcomes in terms of increased risk of paravalvular regurgitation, stroke, and permanent pacemaker implantation. There is no definitive consensus on the optimal sizing method for prosthesis selection in this setting. The LIRA method is a supra-annular tailored sizing method specifically designed for bicuspid anatomy that might increase accuracy of prosthesis choice in BAV patients and improve TAVR outcomes.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!