After years towards higher field strength magnets, nuclear magnetic resonance (NMR) technology in commercial instruments in the past decade has expanded at low and high magnetic fields to take advantage of new opportunities. At lower field strengths, permanent magnets are well established, whereas for midrange and high field, developments utilize superconducting magnets cooled with cryogenic liquids. Recently, the desire to locate NMR spectrometers in nontypical NMR laboratories has created interest in the development of cryogen-free magnets. These magnets require no cryogenic maintenance, eliminating routine filling and large cryogen dewars in the facility. Risks of spontaneous quenches and safety concerns when working with cryogenic liquids are eliminated. The highest field commercially available cryogen-free NMR magnet previously reported was at 4.7 T in 2013. Here we tested a prototype cryogen-free 9.4-T power-driven high-temperature-superconducting (HTS) magnet mated to commercial NMR spectrometer electronics. We chose cinacalcet HCl, a typical active pharmaceutical ingredient, to evaluate its performance towards structure elucidation. Satisfactory standard 1D and 2D homonuclear and heteronuclear NMR results were obtained and compared with those from a standard 9.4-T cryogenically cooled superconducting NMR instrument. The results were similar between both systems with minor differences. Further comparison with different shims and probes in the HTS magnet system confirmed that the magnet homogeneity profile could be matched with commercially available NMR equipment for optimal results. We conclude that HTS magnet technology works well providing results comparable with those of standard instruments, leading us to investigate additional applications for this magnet technology outside a traditional NMR facility.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/mrc.4740 | DOI Listing |
Acc Chem Res
December 2024
Faculty of Chemistry and Food Chemistry, TU Dresden, Bergstrasse 66c, 01069 Dresden, Germany.
ConspectusTriangulene (TRI) and its heterotriangulene (HT) derivatives are planar, triangle-shaped molecules that, via suitable coupling reactions, can form extended organic two-dimensional (2D) crystal (O2DC) structures. While TRI is a diradical, HTs are either closed-shell molecules or monoradicals which can be stabilized in their cationic form.Triangulene-based O2DCs have a characteristic honeycomb-kagome lattice.
View Article and Find Full Text PDFSupercond Sci Technol
November 2024
Francis Bitter Magnet Laboratory/Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.
In this paper, we apply a surface-shunting method to prevent quenches in no-insulation (NI) REBCO magnets triggered by external failures of magnet current leads or power suppliers (i.e., fault mode).
View Article and Find Full Text PDFChemistry
November 2024
Chemistry Department, Bowling Green State University, Bowling Green, Ohio, USA.
A hybrid receptor-sensor for anions originating from the merging of positively charged ammonium moieties for electrostatic attraction/stronger binding of azacrowns with directionality of calixpyrrole hydrogen bond donors for selectivity is investigated. As demonstrated this hybrid receptor-sensor shows a remarkable selectivity for orthophosphate even in the presence of other phosphates and anions found in cellular materials (K HPO >HPO >AMP≫ADP or ATP over halides, nitrate, or hydrogen sulfate; all Na salts in water) but also cellular polyphosphate or phospholipids. This selectivity is harnessed in a real-time monitoring of cell lysis by lysozyme, which releases orthophosphate and other phosphates and anions from the cells.
View Article and Find Full Text PDFMaterials (Basel)
September 2024
Leibniz Institute for Solid State and Materials Research, Helmholtzstr. 20, 01069 Dresden, Germany.
Bulk high-temperature superconductors (HTSs) such as BaCuO (BCO, = Y, Gd) are commonly used in rotationally symmetric superconducting magnetic bearings. However, such bulks have several disadvantages such as brittleness, limited availability and high costs due to the time-consuming and energy-intensive fabrication process. Alternatively, tape stacks of HTS-coated conductors might be used for these devices promising an improved bearing efficiency due to a simplification of manufacturing processes for the required shapes, higher mechanical strength, improved thermal performance, higher availability and therefore potentially reduced costs.
View Article and Find Full Text PDFChemosphere
October 2024
School of Metallurgical and Ecological Engineering, University of Science and Technology Beijing, Beijing, 100083, China. Electronic address:
This study aimed to recover high-purity silica from hematite tailings (HTs) using superconducting high-gradient magnetic separation (S-HGMS) technology. This process involved converting silica into a silicone-rich concentrate and subsequently employing a fluorine-free mixed acid to leach the silicon-rich concentrate to remove impurities and achieve refinement and purification. The optimization of the S-HGMS process was conducted using the "Box-Behnken Design" method, resulting in the following optimal conditions: a pulp concentration of 50 g/L, a magnetic velocity ratio of 0.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!