Bolus timing is critical to optimal magnetic resonance angiography (MRA) acquisitions but can be challenging in some patients. Our purpose was to evaluate whether contrast-enhanced time-resolved magnetic resonance angiography (TR-MRA), a dynamic multiphase sequence that does not rely on bolus timing, is a viable alternative method to conventional 3D fast-long angle shot contrast-enhanced magnetic resonance angiography (CE-MRA). Coronal subtracted conventional CE-MRA images in 50 consecutive patients presenting for pre-atrial fibrillation ablation pulmonary venous (PV) mapping were compared with 50 TR-MRA images performed in 50 subsequent patients. The TR-MRA protocol was modified to optimize spatial resolution with slightly reduced temporal resolution (6.1 s scan time). Three experienced readers evaluated each scan's image quality and relative left atrial (LA) opacification based on a 4-point scale and diagnostic PV visualization in a binary fashion. Additionally, LA signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and PV dimensions were measured for both techniques. TR-MRA had significantly higher overall image quality (3.10 ± 0.69 vs. 2.42 ± 0.69, p < 0.0001), and LA opacification scores (3.33 ± 0.70 vs. 2.15 ± 1.13, p < 0.0001) compared to CE-MRA. The proportion of diagnostically visualized pulmonary veins was 137/150 (91%) in the CE-MRA group vs. 147/150 (98%) with TR-MRA (p = 0.010). Both SNR and CNR were higher with TR-MRA vs. CE-MRA (277.9 ± 48.9 vs. 106.8 ± 41, p = 0.002 and 100.3 ± 41.7 vs. 70.7 ± 48.0, p = 0.002, respectively). Inter-reader variance of individual PV measurements for each of the MR techniques ranged between 0.62 and 1.47 mm and the ICC for vein measurements was higher with TR-MRA (range: 0.62-0.81) compared to CE-MRA (range: 0.47-0.64). TR-MRA, modified to maximize spatial resolution, offers an alternative method for performing high quality MRA examinations in patients with AF. TR-MRA offers greater overall image quality, PV visualization, and similarly reproducible PV measurements compared to traditional CE-MRA, without the challenges of proper bolus timing.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6093807PMC
http://dx.doi.org/10.1007/s10554-018-1355-8DOI Listing

Publication Analysis

Top Keywords

magnetic resonance
16
resonance angiography
16
contrast-enhanced time-resolved
8
time-resolved magnetic
8
bolus timing
8
image quality
8
validation contrast-enhanced
4
magnetic
4
resonance
4
angiography
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!