Measuring Visualized Joint Surface in Hallux Metatarsophalangeal Arthroscopy.

Foot Ankle Int

2 Institute for Foot and Ankle Reconstruction, Mercy Medical Center, Baltimore, MD, USA.

Published: August 2018

Background: Arthroscopy has been increasingly used to evaluate small joints in the foot and ankle. In the hallux metatarsophalangeal (MTP) joint, little data exist evaluating the efficacy of arthroscopy to visualize the articular surface. The goal of this cadaveric study was to determine how much articular surface of the MTP joint could be visualized during joint arthroscopy.

Methods: Ten fresh cadaveric foot specimens were evaluated using standard arthroscopy techniques. The edges of the visualized joint surface were marked with curettes and Kirschner wires; the joints were then surgically exposed and imaged. The visualized surface area was measured using ImageJ software.

Results: On the distal 2-dimensional projection of the joint surface, an average 57.5% (range, 49.6%-65.3%) of the metatarsal head and 100% (range, 100%-100%) of the proximal phalanx base were visualized. From a lateral view of the metatarsal head, an average 72 degrees (range, 65-80 degrees) was visualized out of an average total articular arc of 199 degrees (range, 192-206 degrees), for an average 36.5% (range, 32.2%-40.8%) of the articular arc.

Conclusion: Complete visualization of the proximal phalanx base was obtained. Incomplete metatarsal head visualization was obtained, but this is limited by technique limitations that may not reflect clinical practice.

Clinical Relevance: This information helps to validate the utility of arthrosocpy at the hallux metatarsophalangeal joint.

Download full-text PDF

Source
http://dx.doi.org/10.1177/1071100718770365DOI Listing

Publication Analysis

Top Keywords

visualized joint
12
joint surface
12
hallux metatarsophalangeal
12
metatarsal head
12
mtp joint
8
articular surface
8
proximal phalanx
8
phalanx base
8
degrees range
8
joint
7

Similar Publications

Introduction Excessive repetitive physical activity most often leads to acute musculoskeletal pain. The management of acute pain is one of the primary concerns. The nociceptive pain has both sensory and affective qualities, patterns, and intensity.

View Article and Find Full Text PDF

Background: Prone lateral spinal surgery for simultaneous lateral and posterior approaches has recently been proposed to facilitate surgical room efficiency. The purpose of this study is to evaluate the feasibility and outcomes of minimally invasive prone lateral spinal surgery using a rotatable radiolucent Jackson table.

Methods: From July 2021 to June 2023, a consecutive series of patients who received minimally invasive prone lateral spinal surgery for various etiologies by the same surgical team were reviewed.

View Article and Find Full Text PDF

Arthroscopy is a minimally invasive surgical procedure used to diagnose and treat joint problems. The clinical workflow of arthroscopy typically involves inserting an arthroscope into the joint through a small incision, during which surgeons navigate and operate largely by relying on their visual assessment through the arthroscope. However, the arthroscope's restricted field of view and lack of depth perception pose challenges in navigating complex articular structures and achieving surgical precision during procedures.

View Article and Find Full Text PDF

Background: This study aimed to evaluate the impact of preoperative visual aids on anxiety and pain management in patients with low educational backgrounds undergoing glaucoma filtering surgery.

Methods: A randomized, single-blinded, single-center clinical trial was conducted at a tertiary eye hospital in Shantou, China. Patients scheduled for glaucoma filtering surgery were randomly assigned to either a conventional oral education group or a visual aids group.

View Article and Find Full Text PDF

Whole slide imaging (WSI) provides tissue visualization at the cellular level, thereby enhancing the effectiveness of computer-aided diagnostic systems. High-precision autofocusing methods are essential for ensuring the quality of WSI. However, the accuracy of existing autofocusing techniques can be notably affected by variations in staining and sample heterogeneity, particularly without the addition of extra hardware.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!