Objective: Percutaneous endoscopic lumbar discectomy (PELD) has become a mature and mainstream surgical technique for treating lumbar disc herniation (LDH); however, there is a steep learning curve with PELD, especially for puncture and foraminoplasty. In this study, we assessed the outcome and safety of a novel quantificational and targeted foraminoplasty device named ZESSYS for LDH.

Methods: From September to December of 2016, 70 patients with symptomatic LDH were enrolled in the study. The patients were assigned randomly to either the ZESSYS group or the conventional TESSYS group. We recorded the cannula introduction time, decompression time, radiation exposure time, intraoperative pain feeling score, visual analog scale, Oswestry Disability Index, and Macnab criteria score of the 2 groups. The mean follow-up period was 14 months.

Results: The average cannula introduction time (16.50 ± 3.29 minutes) and the radiation exposure time (40.71 ± 6.23 seconds) in the ZESSYS group were significantly reduced compared with the TESSYS group (cannula introduction time, 20.06 ± 3.37 minutes, P = 0.000; radiation exposure time, 49.20 ± 7.84 seconds, P = 0.000). Intraoperative pain feeling score in the ZESSYS group was significantly improved compared with the TESSYS group (P = 0.021). There were no significant differences between the 2 groups for decompression time (P = 0.617), Macnab criteria (P = 0.769), or visual analog scale and Oswestry Disability Index scores at the same time point (P > 0.05). No serious complication was observed in any patients in either group.

Conclusions: The novel targeted foraminoplasty technique with the specially designed double-cannulas is an effective and safe treatment for lumbar intervertebral disc herniation. It reduces the difficulty of PELD learning, minimizes radiation exposure, and decreases intraoperative pain associated with foraminoplasty.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.wneu.2018.04.032DOI Listing

Publication Analysis

Top Keywords

radiation exposure
16
targeted foraminoplasty
12
zessys group
12
tessys group
12
cannula introduction
12
introduction time
12
exposure time
12
intraoperative pain
12
time
9
novel targeted
8

Similar Publications

Background: Exposure to ionizing radiation is inevitable due to its extensive use in industrial and medical applications. The search for effective and safe natural therapeutic agents as alternatives to chemical drugs is crucial to mitigate their side effects. This study aimed to evaluate the effects of citicoline as a standalone treatment or in combination with the anti-hepatotoxic drug silymarin in protecting against liver injury caused by γ-radiation in rats.

View Article and Find Full Text PDF

Atlantoaxial dislocation (AAD) is a serious condition in which the first two cervical vertebrae lose their anatomical position and stability. This may lead to neurological complications, including death. The treatment of AAD remains controversial, and posterior instrumentation with pedicle screw placement is one of the commonly used methods.

View Article and Find Full Text PDF

Background: Despite patent ductus arteriosus closure in premature infants is a relatively fast procedure, it involves specific steps for equipment exchange and the use of a 4-Fr catheter, which may be large for tiny infants, potentially causing haemodynamic instability or tricuspid valve regurgitation.

Objectives: This study aims to describe the early experience with a new technique designed to simplify transcatheter patent ductus arteriosus closure in premature infants. It enables the closure using the KA micro plug device via a single microcatheter without equipment exchanges and contrast exposure.

View Article and Find Full Text PDF

Photon-counting mammography is an emerging modality that allows for spectral imaging and provides a differentiation of material compositions. The development of photon-counting mammography-specific contrast agents has yet to be explored. In this study, the contrast, sensitivity, and organ dose between silver sulfide nanoparticles (AgS-NPs) and a clinically approved iodinated agent (iopamidol) were investigated using a contrast-embedded gradient ramp phantom and a prototype scanner.

View Article and Find Full Text PDF

The effects of age and other individual factors on radiation induced ESR signals from fingernails.

Front Public Health

January 2025

Department of Radiation Biophysics, Research Institute for Radiation Biology and Medicine (RIRBM), Hiroshima University, Hiroshima, Japan.

Biodosimetry is crucial for assessing ionizing radiation exposure to guide medical responses. Electron spin resonance (ESR) spectroscopy using fingernails can be effectively used for both occupational and public dose assessments in radiological accidents because of their accessibility and ability to retain stable radiation-induced free radicals. However, despite two decades of research, challenges remain in achieving accurate fingernail dosimetry, mainly owing to the variation in ESR signals among individuals.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!