Objective: Whether the aortopathy associated with bicuspid aortic valve (BAV) disease occurs secondary to genetic or hemodynamic factors remains controversial. In this article we describe the natural history of the aortic root in patients with bicuspid versus tricuspid aortic valves (TAVs) after replacement of the aortic valve and ascending aorta.
Methods: From 1990 to 2010, 406 patients (269 BAV, 137 TAV) underwent aortic valve and ascending aorta replacement at a single institution. Patients with aortic dissection, endocarditis, previous aortic surgery, or Marfan syndrome were excluded. All available follow-up imaging was reviewed.
Results: Mean imaging follow-up was 5.5 (±5.3) years. Of all patients, 66.5% had at least 1 aortic root measurement after the index operation. Baseline aortic diameter was comparable between groups. In patients with BAV, aortic root diameter increased at a clinically negligible rate over time (0.654 mm per year; 95% confidence interval, 0.291-1.016; P < .001), similar to patients with TAV (P = .92). Mean clinical follow-up was 8.1 (±5.4) years. During follow-up, 18 patients underwent reoperation, 89% for a degenerated bioprosthetic aortic valve. Only 1 patient underwent reoperation for a primary indication of aortic aneurysmal disease, 22 years after the index operation. There were no differences in cumulative incidence rates of aortic reoperation (P = .14) between patients with BAV and TAV.
Conclusions: Mid-term imaging after aortic valve and ascending aorta replacement indicates that if the aortic root is not dilated at the time of surgery, the risk of enlargement over time is minimal, negating the need for prophylactic root replacement in patients with BAV or TAV.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jtcvs.2018.02.094 | DOI Listing |
J Cardiothorac Surg
January 2025
Department of Cardiovascular Surgery, West China Hospital of Sichuan University, 37# Guoxue Xiang, Chengdu, 610041, Sichuan, China.
Background: Pseudoaneurysm after coarctation of the aorta (CoA) repair is a rare but severe complication. Contributing factors may include infection, hypertension, aortic wall weakness, and turbulent blood flow at the repair site.
Case Presentation: A 35-year-old male presented with recurrent episodes of epistaxis and dizziness was admitted to the emergency department.
Sci Rep
January 2025
Department of Engineering Mechanics, KTH Royal Institute of Technology, Stockholm, Sweden.
Aneurysm rupture is a life-threatening event, yet its underlying mechanisms remain largely unclear. This study investigated the fracture properties of the thoracic aneurysmatic aorta (TAA) using the symmetry-constraint Compact Tension (symconCT) test and compared results to native and enzymatic-treated porcine aortas' tests. With age, the aortic stiffness increased, and tissues ruptured at lower fracture energy [Formula: see text].
View Article and Find Full Text PDFAppl Biochem Biotechnol
January 2025
University of South China, Hengyang, Hunan, China.
The study was designed to investigate the impact of N6-methyladenosine (m6A) writer Wilms tumor 1-associated protein (WTAP) on the progression of atherosclerosis (AS) and to further elucidate its possible regulatory mechanism. The m6A levels and WTAP expressions were initially assessed through RIP, qRT-PCR, and western blotting. An in vitro model of AS was constructed by ox-LDL treatment in RAW264.
View Article and Find Full Text PDFJ Med Genet
January 2025
Center of Medical Genetics, University of Antwerp and Antwerp University Hospital, Antwerp, Belgium.
Background: Individuals harbouring pathogenic variants are at risk for aneurysms/dissections throughout the arterial tree. Based on prior reports of sex differences in thoracic aortic aneurysm/dissection, we investigated the sexual dimorphism for vascular events in variant-harbouring patients.
Methods: We analysed two large pedigrees comprising 84 individuals segregating pathogenic missense variants affecting the same p.
A A Pract
January 2025
Department of Anesthesiology, University of Kansas Medical Center, Kansas City, Kansas.
Transcatheter aortic valve replacement (TAVR) is a common treatment for severe aortic stenosis (AS), but it carries the risk of severe complications, including device embolization. We present a case of a TAVR valve embolization into the left ventricular outflow tract (LVOT), diagnosed with transesophageal echocardiography (TEE) shortly after device deployment. The dislodged valve was successfully retrieved from the LVOT into the aorta, flattened, and stabilized with a thoracic endovascular aneurysm repair (TEVAR) stent, enabling the successful implantation of a new TAVR valve.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!