A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Robust workflow and instrumentation for cryo-focused ion beam milling of samples for electron cryotomography. | LitMetric

Electron cryotomography is able to visualize macromolecular complexes in their cellular context, in a frozen-hydrated state, and in three dimensions. The method, however, is limited to relatively thin samples. Cryo-focused ion beam (FIB) milling is emerging as a powerful technique for sample thinning prior to cryotomography imaging. Previous cryo-FIB milling reports utilized custom-built non-standard equipment. Here we present a workflow and the required commercially available instrumentation to either implement the method de novo, or as an upgrade of pre-existing dual beam milling instruments. We introduce two alternative protocols and the respective sample holders for milling. The "bare grid holder" allows for milling on plain grids, having the advantage of enabling relatively shallow milling angles for wedge geometries. The "Autogrid holder" is designed for milling grids clamped into a mechanical support ring (Autogrid), resulting in increased stability for lamella geometries. We applied the workflow to prepare samples and record high-quality tomograms of diverse model organisms, including infected and uninfected HeLa cells, amoebae, yeast, multicellular cyanobacteria, Pseudomonas aeruginosa and Escherichia coli cells. The workflow will contribute to the dissemination of electron cryotomography of cryo-FIB milled samples in the biological sciences.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ultramic.2018.04.002DOI Listing

Publication Analysis

Top Keywords

electron cryotomography
12
cryo-focused ion
8
ion beam
8
milling
8
beam milling
8
robust workflow
4
workflow instrumentation
4
instrumentation cryo-focused
4
samples
4
milling samples
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!