MRI screening of high-risk patients for breast cancer provides very high sensitivity, but with a high recall rate and negative biopsies. Comparing the current exam to prior exams reduces the number of follow-up procedures requested by radiologists. Such comparison, however, can be challenging due to the highly deformable nature of breast tissues. Automated co-registration of multiple scans has the potential to aid diagnosis by providing 3D images for side-by-side comparison and also for use in CAD systems. Although many deformable registration techniques exist, they generally have a large number of parameters that need to be optimized and validated for each new application. Here, we propose a framework for such optimization and also identify the optimal input parameter set for registration of 3D T-weighted MRI of breast using Elastix, a widely used and freely available registration tool. A numerical simulation study was first conducted to model the breast tissue and its deformation through finite element (FE) modeling. This model generated the ground truth for evaluating the registration accuracy by providing the deformation of each voxel in the breast volume. An exhaustive search was performed over various values of 7 registration parameters (4050 different combinations of parameters were assessed) and the optimum parameter set was determined. This study showed that there was a large variation in the registration accuracy of different parameter sets ranging from 0.29 mm to 2.50 mm in median registration error and 3.71 mm to 8.90 mm in 95 percentile of the registration error. Mean registration errors of 0.32 mm, 0.29 mm, and 0.30 mm and 95 percentile errors of 3.71 mm, 5.02 mm, and 4.70 mm were obtained by the three best parameter sets. The optimal parameter set was applied to consecutive breast MRI scans of 13 patients. A radiologist identified 113 landmark pairs (~ 11 per patient) which were used to assess registration accuracy. The results demonstrated that using the optimal registration parameter set, a registration accuracy (in mm) of 3.4 [1.8 6.8] was achieved.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6148821 | PMC |
http://dx.doi.org/10.1007/s10278-018-0063-1 | DOI Listing |
Sci Data
January 2025
Institute of Physics, Faculty of Science, Pavol Jozef Šafárik University in Košice, Park Angelinum 9, 041 54, Košice, Slovak Republic.
The present work describes the process of the creation and analysis of the first dataset containing processing parameters and functional properties of soft magnetic composites (SMC). All data were obtained experimentally using Fe-3% MgO system. When creating samples, parameters such as a size of MgO nanoparticles, pressing pressure, sintering temperature, time and atmosphere were varied.
View Article and Find Full Text PDFJ Nephrol
January 2025
Department of Medicine, Surgery and Neurosciences, Nephrology, Dialysis and Transplantation Unit, University Hospital of Siena, Siena, Italy.
Background: Renal functional reserve (RFR) measures the difference between the stimulated glomerular filtration rate (GFR) and the baseline GFR to detect early signs of renal functional decline. The protein load test (RFR-T) is the gold standard for RFR assessment but is a complicated procedure. Renal intraparenchymal resistance index (RRI) variation test (DRRI-T) is a non-invasive method to measure renal function reserve using ultrasound.
View Article and Find Full Text PDFAcad Radiol
January 2025
Department of Radiology, Shengjing Hospital of China Medical University, China (Y.Y., T.W.). Electronic address:
Rationale And Objectives: Mixed ground-glass nodules (mGGNs) are highly malignant and common nonspecific lung imaging findings. This study aimed to explore whether combining quantitative and qualitative spectral dual-layer detector-based computed tomography (SDCT)-derived parameters with serological tumor abnormal proteins (TAPs) and thymidine kinase 1 (TK1) expression enhances invasive mGGN diagnostic efficacy and to develop a joint diagnostic model.
Materials And Methods: This prospective study included patients with mGGNs undergoing preoperative triple-phase contrast-enhanced SDCT with TAP and TK1 tests.
Women Birth
January 2025
Department of Nursing and Midwifery Education and Research, King Edward Memorial Hospital, Subiaco, Australia; School of Nursing, Curtin University, Bentley, Australia.
Problem: It is unknown whether the deployment of registered nurses to assist midwives in the provision of postnatal care eases the burden of workforce shortages.
Background: The largest public maternity health service in Western Australia began employing registered nurses in 2022 to assist midwives with the provision of postnatal care on maternity wards in response to staffing shortages, exacerbated by COVID-19.
Aim: To explore midwives' and registered nurses' experiences of providing postnatal care on maternity wards together.
J Forensic Odontostomatol
December 2024
Faculdade de Medicina Dentária da Universidade do Porto.
The activity of a dentist reveals itself in numerous aspects, and its regulation is determined by the Deontological Code of the Dental Association, which contains a set of rules that dentists are obliged to follow in the exercise of their profession. The regulation of this activity goes beyond following these precepts because, in the legal relationship that is established whenever an agreement is made with a patient to carry out the treatment deemed appropriate, a series of duties and obligations begin for each party, translated into a reciprocal contract, in which the non-compliance of one of them may result in a legal claim. The objective of this study was to research most court decisions delivered in this century, in Portugal, regarding the activity of dentists when faced with patient claims and to outline a framework that better allows us to understand the regulation of this activity within the scope of the contracts established with them.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!