  • Gingival melanin hyperpigmentation is an aesthetic issue, and this study evaluated three treatment methods: surgical stripping and two Er,Cr:YSGG laser settings.
  • The results indicated laser setting 1 provided better pain management and patient satisfaction, while both laser methods improved wound healing compared to surgical stripping.
  • Laser setting 2 had the least bleeding and effective coagulation, while both laser methods showed lower pigmentation scores after 1 and 12 months, with laser setting 1 having the best results overall.

Article Abstract

Gingival melanin hyperpigmentation is an esthetic concern for many individuals. In this study, we compared the standard surgical removal method with two different Er,Cr:YSGG laser settings in order to find the best treatment method. In 33 dental arches, the following three treatment groups were comparatively evaluated: (1) surgical stripping, (2) removal with laser setting 1 (4.5 W, 50 Hz, 100% water, 80% air, 60 μs, 800 μm Tip; MZ8), and (3) laser setting 2 (2.5 W, 50 Hz, 20% water, 40% air, 700 μs, 800 μm Tip; MZ8). We comparatively evaluated pain, patient satisfaction and wound healing, treatment time, and the amount of bleeding. Re-pigmentation was evaluated after 1 and 12 months by Hedin and Dummet pigmentation scores. Laser setting 1 had the best results regarding pain and patient satisfaction, although not statistically significant (P > 0.05). Wound healing results were better using lasers compared to surgical stripping (P < 0.05). Laser setting 1 was a faster procedure with mild amounts of bleeding. The least amount of bleeding was seen with laser setting 2. After 1 month, only two cases of the laser setting 2-treated areas showed an isolated pigmented area in the papilla; at 12 months, the mean Hedin indexes were still less than 2 and mean Dummett index less than 1 in all treatment techniques, with the lowest scores seen in the laser setting 1 sites. Based on our results, Er,Cr:YSGG laser can be more convenient for gingival depigmentation compared to surgical blade. Although not statistically significant, laser setting 1 with shorter pulse duration and higher water spray showed better overall results. However, laser setting 2, with longer pulse duration and less water spray, resulted in better coagulative effects and can be used to control bleeding wherever necessary in clinical practice.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10103-018-2501-1DOI Listing

Publication Analysis

Top Keywords

surgical stripping
12
laser setting
12
ercrysgg laser
8
comparatively evaluated
8
800 μm mz8
8
pain patient
8
patient satisfaction
8
wound healing
8
laser
5
comparison gingival
4

Similar Publications

Diaphragmatic stripping versus full-thickness diaphragmatic resection in cytoreductive surgery: a meta-analysis of the current evidence.

Langenbecks Arch Surg

January 2025

Department of Surgery (A), Medical Faculty and University Hospital Duesseldorf, Heinrich-Heine-University, Moorenstr. 5, 40225, Duesseldorf, Germany.

Purpose: The primary objective was to compare the intra- and postoperative outcomes of diaphragmatic stripping versus full-thickness diaphragmatic resection in patients with peritoneal carcinomatosis who underwent cytoreductive surgery.

Methods: According to the PRSIMA guidelines, a comprehensive literature search was conducted for studies comparing postoperative pulmonary complications as well as intra- and postoperative outcomes of diaphragmatic stripping versus full-thickness diaphragmatic resection in patients with peritoneal carcinomatosis necessitating cytoreductive surgery. Data from eligible studies were extracted, qualitatively assessed, and included in a meta-analysis.

View Article and Find Full Text PDF

Purpose: To analyze the outcomes of corneal transplantation procedures over a 13-year period at Farabi Eye Hospital, Tehran, Iran, to identify trends and determinants influencing the frequency and success of primary and re-transplantations.

Methods: Utilizing a comprehensive dataset from the hospital's Hospital Information System, the study reviewed the records of 8,378 patients who underwent corneal transplants between 2009 and 2022. This analysis included demographic information, surgical details, and follow-up data.

View Article and Find Full Text PDF

Currently, Unilateral biportal endoscopy is widely used in the surgical treatment of lumbar spinal stenosis. To investigate the feasibility of bilateral synchronous UBE to unilateral laminotomy and bilateral decompression(BS-UBE-ULBD) for treating two-level lumbar spinal stenosis (LSS). Sixty-four patients with two-level lumbar spinal stenosis (LSS) treated with BS-UBE-ULBD from October 2022 to January 2024 were retrospectively analyzed.

View Article and Find Full Text PDF

Purpose: This study aimed to describe a novel technique of direct anterior chamber (AC) air replacement (DACAR) for the management of Descemet stripping automated endothelial keratoplasty (DSAEK) in postvitrectomized eyes and eyes with previous glaucoma surgery.

Methods: DACAR was performed after a corneal donor graft was transplanted through a wound using the pull-through technique. DACAR involves stabilizing the graft with forceps while introducing air into the AC via an infusion cannula to ensure complete air exchange.

View Article and Find Full Text PDF

Introduction: Room air class (RC) Ib may be necessary for surgical procedures in aseptic working areas. The aim of the study was to examine whether a mobile, three-stage sterile ventilation unit (MSVU) can replace a room ventilation system (RVS) with turbulent mixed flow (TMF) in the area of the operating field and on the instrument table from hygienic-microbiological point of view.

Method: During 26 surgeries (varicose vein stripping or treatment of umbilical and inguinal hernias), the microbial load was recorded at 4 measuring points (M1-M4) during regular operations by setting up sedimentation plates and measuring the particle concentration.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!