Background: Impaired left ventricular (LV) ejection fraction is a common finding in patients with aortic stenosis and serves as a predictor of morbidity and mortality after transcatheter aortic valve replacement. However, conflicting data on the most accurate measure for LV function exist. We wanted to examine the impact of LV ejection fraction, mean pressure gradient, and stroke volume index on the outcome of patients treated by transcatheter aortic valve replacement.
Methods And Results: Patients treated by transcatheter aortic valve replacement were primarily separated into normal flow (NF; stroke volume index >35 mL/m) and low flow (LF; stroke volume index ≤35 mL/m). Afterwards, patients were divided into 5 groups: "NF-high gradient," "NF-low gradient" (NF-LG), "LF-high gradient," "paradoxical LF-LG," and "classic LF-LG." The 3-year mortality was the primary end point. Of 1600 patients, 789 (49.3%) were diagnosed as having LF, which was characterized by a higher 30-day (=0.041) and 3-year (<0.001) mortality. LF was an independent predictor of all-cause (hazard ratio, 1.29; 95% confidence interval, 1.03-1.62; =0.03) and cardiovascular (hazard ratio, 1.37; 95% confidence interval, 1.06-1.77; =0.016) mortality. Neither mean pressure gradient nor LV ejection fraction was an independent predictor of mortality. Patients with paradoxical LF-LG (35.0%), classic LF-LG (35.1%) and LF-high gradient (38.1%) had higher all-cause mortality at 3 years compared with NF-high gradient (24.8%) and NF-LG (27.9%) (=0.001). However, surviving patients showed a similar improvement in symptoms regardless of aortic stenosis entity.
Conclusions: LF is a common finding within the aortic stenosis population and, in contrast to LV ejection fraction or mean pressure gradient, an independent predictor of all-cause and cardiovascular mortality. Despite increased long-term mortality, high procedural success and excellent functional improvement support transcatheter aortic valve replacement in patients with LF severe aortic stenosis.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6015421 | PMC |
http://dx.doi.org/10.1161/JAHA.117.007977 | DOI Listing |
Eur Heart J Case Rep
January 2025
The Second Department of Internal Medicine, University of Toyama, 2630 Sugitani, Toyama, Toyama 930-0194, Japan.
Background: Self-expanding valves used in transcatheter aortic valve implantation (TAVI) are designed to allow recapture and repositioning, facilitating optimal placement and mitigating conduction disturbances and paravalvular leakage. Here, we present a rare case in which the Navitor (Abbott Structural Heart, Santa Clara, CA, USA) could not be recaptured.
Case Summary: An 81-year-old Japanese woman with very severe aortic stenosis and a massively calcified nodule at the non-coronary cusp (NCC) underwent TAVI with a 25 mm Navitor valve.
Eur Heart J Case Rep
January 2025
Tehran Heart Center, Cardiovascular Diseases Research Institute, Tehran University of Medical Sciences, North Kargar Ave, Tehran 1411713138, Iran.
Background: Since the transcatheter valve-in-valve (ViV) procedure was introduced in 2007, a few cases of infective endocarditis (IE) following the ViV procedure have been reported, which can be predisposed by older age, pre-existing medical conditions, and procedural techniques. Paravalvular abscesses constitute a rare complication of IE, resulting from extending IE beyond the valve annulus, less commonly caused by species. This complication is more common in prosthetic valves, particularly bioprosthetic valves.
View Article and Find Full Text PDFCJC Open
January 2025
Department of Cardiology, Royal North Shore Hospital, Sydney, Australia.
CJC Open
January 2025
Interventional Cardiology Service, Centro Medico Nacional 20 de Noviembre, Mexico City, Mexico.
Trauma Case Rep
February 2025
Department of Emergency and Critical Care Medicine, Hyogo Emergency Medical Center, 1-3-1 Wakinohamakaigandori, Chuo-ku, Kobe, Hyogo 651-0073, Japan.
Background: Hybrid emergency rooms (ERs) allow computed tomography (CT) scanning, interventional radiology, and surgery all in the same suite. Severe trauma patients with blunt thoracic aortic injury (BTAI) require rapid diagnosis and treatment. Hybrid ERs allow the potential for clinicians to implement multiple therapeutic procedures, including thoracic endovascular aortic repair (TEVAR), for these types of conditions without the need to transport the patients.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!