Background: The purpose of this research was to assess agreement between four rating systems of cosmetic outcome measured in a subset of patients with early breast cancer participating in the randomised TARGIT-A trial. TARGIT-A compared risk-adapted single-dose intra-operative radiotherapy (TARGIT-IORT) to whole breast external beam radiotherapy (EBRT).
Methods: Patients, their Radiation Oncologist and Research Nurse completed a subjective cosmetic assessment questionnaire before radiotherapy and annually thereafter for five years. Objective data previously calculated by the validated BCCT.core software which utilizes digital photographs to score symmetry, colour and scar was also used. Agreement was assessed by the Kappa statistic and longitudinal changes were assessed by generalized estimating equations.
Results: Overall, an Excellent-Good (EG) cosmetic result was scored more often than a Fair-Poor (FP) result for both treatment groups across all time points, with patients who received TARGIT-IORT scoring EG more often than those who received EBRT however this was statistically significant at Year 5 only. There was modest agreement between the four rating systems with the highest Kappa score being moderate agreement which was between nurse and doctor scores at Year 1 with Kappa = 0.46 (p < 0.001), 95% CI (0.24, 0.68).
Conclusion: Despite similar overall findings between treatment groups and rating systems, the inter-rater agreement was only modest. This suggests that the four rating systems utilized may not necessarily be used interchangeably and it is arguable that for an outcome such as cosmetic appearance, the patient's point of view is the most important.
Trial Registration: TARGIT-A ISRCTN34086741 , Registered 21 July 2004, retrospectively registered.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5899392 | PMC |
http://dx.doi.org/10.1186/s13014-018-0998-x | DOI Listing |
Curr Drug Deliv
January 2025
Department of Pharmaceutics, Y. B. Chavan College of Pharmacy, Aurangabad, India.
Pharmaceutical giants (e.g., Ashland, Bausch & Lomb, Johnson & Johnson, Medtronic, Neurelis, etc.
View Article and Find Full Text PDFLasers Surg Med
January 2025
Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, Massachusetts, USA.
Objectives: This work highlights the methods used to develop a multi-pulse 1726 nm laser system combined with bulk air-cooling for selective sebaceous gland (SG) photothermolysis using thermal imaging and software algorithms. This approach enables treating to a desired tissue temperature and depth to provide a safe, effective, reproducible, and durable treatment of acne.
Methods: We designed and built a 1726 nm laser system with a 40 W maximum power output, a highly controlled air-cooling device, and a thermal camera in the handpiece, which permits real-time temperature monitoring of the epidermis.
Asian J Endosc Surg
January 2025
Department of Pediatric Surgery, Research Field in Medical and Health Sciences, Medical and Dental Area, Research and Education Assembly, Kagoshima University, Kagoshima, Japan.
Many institutions perform thoracoscopic surgery for pediatric extrapulmonary sequestration (EPS). This approach achieves good cosmetic outcomes due to the small skin incision in comparison to open surgery. However, an extension or additional incision is sometimes necessary to extract resected specimens from the thoracic cavity, which reduces the advantages of this procedure.
View Article and Find Full Text PDFArthroscopy
January 2025
Assistant Professor, Division of Shoulder and Elbow Surgery, Department of Orthopaedic Surgery, University of Missouri School of Medicine, Columbia, Missouri, United Stated.
The long head of the biceps tendon (LHBT) is a common source of anterior shoulder pain, frequently addressed during rotator cuff repairs. Surgical management typically involves either tenotomy or tenodesis, each offering distinct advantages and disadvantages. Tenotomy, a straightforward procedure with a short rehabilitation period, is well-suited for low-demand patients but carries a higher risk of Popeye deformity and cramping pain.
View Article and Find Full Text PDFN Engl J Med
January 2025
From the University of Queensland, Brisbane, QLD, Australia (A.J.U., D.A., T.M.K., N.M., N.R., P.L.-A., V.G., A.C., P.M., C.M.R., P.N.A.H.); Children's Health Queensland Hospital and Health Service, Brisbane, QLD, Australia (A.J.U., T.M.K., P.L.-A., V.G.); Griffith University, Brisbane, QLD, Australia (A.J.U., D.A., T.M.K., R.M.W., N.M., A.C.B., R.R., J.B., V.C., C.M.R., R.S.W.); Royal Brisbane and Women's Hospital, Brisbane, QLD, Australia (A.J.U., T.M.K., N.M., K.S., A.C., P.N.A.H.); Princess Alexandra Hospital, Brisbane, QLD, Australia (R.M.W., B.P., N.R., J.L., C.B., P.M.); University of Colorado, Denver (V.C.); and Metro North Health, Brisbane, QLD, Australia (C.M.R.).
Background: New catheter materials for peripherally inserted central catheters (PICCs) may reduce the risk of device failure due to infectious, thrombotic, and catheter occlusion events. However, data from randomized trials comparing these catheters are lacking.
Methods: We conducted a randomized, controlled, superiority trial in three Australian tertiary hospitals.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!