A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@remsenmedia.com&api_key=81853a771c3a3a2c6b2553a65bc33b056f08&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Usefulness of Sofia Pneumococcal FIA® test in comparison with BinaxNOW® Pneumococcal test in urine samples for the diagnosis of pneumococcal pneumonia. | LitMetric

The Sofia Pneumococcal FIA® test is a recently introduced immunofluorescent assay automatically read aimed to detect Streptococcus pneumoniae antigen in urine. The aim of this study was to evaluate the usefulness of SofiaFIA® urinary antigen test (UAT) in comparison with classical immunochromatographic BinaxNOW® test for the diagnosis of pneumococcal pneumonia (PP). Observational study was conducted in the Hospital Universitari Vall d'Hebron from December 2015 to August 2016. Consecutive adult patients diagnosed of pneumonia and admitted to the emergency department in whom UAT was requested were prospectively enrolled. Paired pneumococcal UAT was performed (BinaxNOW® and SofiaFIA®) in urine samples. To assess the performance of both tests, patients were categorized into proven PP (isolation of S. pneumoniae in sterile fluid) or probable PP (isolation of S. pneumoniae in respiratory secretion). Sensitivity, specificity, and concordance were calculated. A total of 219 patients with pneumonia were enrolled, of whom 14% had a proven or probable PP, 22% a non-pneumococcal etiology, and 64% an unidentified pathogen. Concordance between tests was good (κ = 0.81). Sensitivity of SofiaFIA® and BinaxNOW® UAT was 78.6 and 50% for proven PP (p = 0.124), and 74.2 and 58% for proven/probable PP (p = 0.063). Specificity for both tests was 83.3 and 85.5% for proven and proven/probable PP. In patients without an identified pathogen, SofiaFIA® test was positive in 33 (23.6%) cases and BinaxNOW® in 25 (17.8%), so Sofia Pneumococcal FIA® detected 32.6% more cases than BinaxNOW® (p = 0.001). Sofia Pneumococcal FIA® test showed an improved sensitivity over visual reading of BinaxNOW® test without a noticeable loss of specificity.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10096-018-3248-0DOI Listing

Publication Analysis

Top Keywords

sofia pneumococcal
16
pneumococcal fia®
16
fia® test
12
test
8
urine samples
8
diagnosis pneumococcal
8
pneumococcal pneumonia
8
binaxnow® test
8
isolation pneumoniae
8
cases binaxnow®
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!