Background: The aim of this study was to evaluate the effectiveness of two diagnostic tests routinely used for diagnosing carpal tunnel syndrome (CTS)-ultrasonography (US) and nerve conduction studies (NCS)-by comparing their accuracy based on surgical results, with the remission of paresthesia as the reference standard.
Methods: We enrolled 115 patients, all of the female gender with a high probability of a clinical diagnosis of CTS. All patients underwent US and NCS for a diagnosis and subsequent surgical treatment. As a primary outcome, the accuracy of the US and NCS diagnoses was measured by comparing their diagnoses compared with those determined by the surgical outcomes. Their accuracy was secondarily evaluated based on before and after scores of the Boston Carpal Tunnel Questionnaire (BCTQ).
Results: Overall, 104 patients (90.4%) were diagnosed with CTS by the surgical reference standard, 97 (84.3%) by NCS, and 90 (78.3%) by US. The concordance of NCS and surgical treatment (p < 0.001; kappa = 0.648) was superior to that of US and surgical treatment (p < 0.001; kappa = 0.423). The sensitivity and specificity of US and NCS were similar (p = 1.000 and p = 0.152, respectively: McNemar's test). The BCTQ scores were lower after surgery in patients diagnosed by both US and NCS (p < 0.001and p < 0.001, respectively: analysis of variance).
Conclusions: US and NCS effectively diagnosed CTS with good sensitivity but were not effective enough to rule out a suspicion of CTS.
Trial Registration: This study was registered at September, 10 th, 2015, and the registration number was NCT02553811 .
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5898048 | PMC |
http://dx.doi.org/10.1186/s12891-018-2036-4 | DOI Listing |
Hand Surg Rehabil
January 2025
Centre Hospitalier Régional Universitaire de Nîmes, Department of Orthopaedic Surgery, Nîmes, France.
Dynamic compression of the median nerve under the lacertus fibrosus at the elbow causes pain and weakness. It is a frequently overlooked pathology and a cause of failed recovery after carpal tunnel release. The purpose was to present a technical note on minimally invasive ultrasound-guided lacertus syndrome surgical treatment under WALANT.
View Article and Find Full Text PDFCureus
December 2024
Department of Orthopedic Surgery, University of Rochester Medical Center, Rochester, USA.
Introduction: This study sought to investigate the impact of the area deprivation index (ADI) on the treatment timeline from carpal tunnel syndrome (CTS) to carpal tunnel release (CTR). We hypothesize that increased social deprivation will correlate with increased time between care milestones from presentation to surgery.
Methods: This is a retrospective review of patients diagnosed with CTS who underwent CTR at a single academic institution.
S D Med
November 2024
Sanford Orthopedics and Sports Medicine, Sioux Falls, South Dakota.
Amyloidosis is a deadly systemic disease in which misfolded proteins accumulate in human tissue eventually leading to morbid dysfunction in multiple organ systems. The prognosis of untreated amyloidosis is poor. Orthopedic manifestations of amyloidosis include carpal tunnel syndrome (CTS), trigger digit, distal biceps tendon rupture, rotator cuff disease, and lumbar spinal stenosis.
View Article and Find Full Text PDFJ Hand Surg Asian Pac Vol
January 2025
Ogori Daiichi General Hospital, Yamaguchi-ken, Japan.
In carpal tunnel syndrome (CTS), pain and sensory disturbance are the main symptoms, but thumb palmar abduction (TPA) paralysis cannot be ignored as a concurrent symptom. The reliable quantitative measurement of TPA power was not established. The purpose of this study was to report on the reliability of TPA strength measurements by the hand-held dynamometry (HHD) in large samples of CTS and its superiority over other tests, including grip, pinch powers, TPA angles and manual muscle testing, in terms of clinical progress indicators.
View Article and Find Full Text PDFSmall Methods
January 2025
School of Mechanical Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea.
Flexible tactile sensors have received significant attention for use in wearable applications such as robotics, human-machine interfaces, and health monitoring. However, conventional tactile sensors face challenges in accurately measuring pressure because vertical deformation is induced by Poisson's ratio in situations where lateral strain is applied. This study shows a strain-insensitive flexible tactile sensor array without the crosstalk effect using a highly stretchable mesh.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!