Background And Aims: Central venous cannulation (CVC) through right internal jugular vein (IJV) route is routinely performed in paediatric patients undergoing major surgery and in those admitted to intensive care units. A novel technique (modified short-axis out-of-plane [MSA-OOP]) to improve first pass success rate of ultrasound-guided IJV CVC in neonates and infants is being compared with conventional SA-OOP method.
Methods: A total of 120 patients were enroled in the study over a period of 6 months. All paediatric patients with age <1 year and weight <10 kg who underwent a major surgery requiring CVC were included. Patients were randomised to either of the two approaches of ultrasound-guided IJV cannulation; SA-OOP and modified SA-OOP (MSA-OOP). In modified approach, the midline of probe footprint was marked with a radio-opaque barium wire that casted a central acoustic shadow on ultrasound screen.
Results: In MSA-OOP group, 83.1% of patients were cannulated in the first attempt as compared to 49.2% patients in group SA-OOP. Patients in MSA-OOP group required significantly fewer attempts for successful CVC as compared to patients in the SA-OOP group ( MSA-OOP: median = 1, interquartile range [1-1]; SAOOP: median = 2, interquartile range [1-2], < 0.001, Mann-Whitney U-test).
Conclusion: The use of MSA-OOP ultrasound technique for IJV CVC cannulation results in a higher first-attempt success rate and reduces the number of cannulation attempts.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5881323 | PMC |
http://dx.doi.org/10.4103/ija.IJA_676_17 | DOI Listing |
Cureus
January 2025
Physiology, Thomas F. Frist, Jr. College of Medicine, Nashville, USA.
Subconcussive impacts are very common in the sports world and can have many negative impacts on human function, including increased risk for cognitive decline and behavioral impairments such as chronic traumatic encephalopathy (CTE). The purpose of this article is to analyze the available literature on the effects of jugular vein compression applied by a cervical collar on cerebral structure and function in the setting of chronic impact exposure. This narrative review analyzed 17 articles on brain structure and function, published between 1992 and 2022.
View Article and Find Full Text PDFJ Cardiothorac Vasc Anesth
January 2025
Department of Cardiac Anesthesia, King Abdullah Medical City in Holy Capital KAMC-HC, Makkah, Saudi Arabia. Electronic address:
Objective(s): Previous literature suggested the advantage of combined short-long axis (CSLA) technique to avoid posterior wall puncture during internal jugular vein (IJV) cannulation. The purpose of this study is to define the best ultrasound-guided IJV cannulation technique regarding the success rate in the first trial of insertion, time to successful central line placement, number of attempts, procedural complications, and operator satisfaction.
Design: Single-blinded, prospective randomized clinical trial.
Rev Gastroenterol Peru
January 2025
Centro de Gastroenterología, Bogotá, Colombia; Gastroenterología y endoscopia digestiva, Universidad Nacional de Colombia, Bogotá, Colombia; Gastroenterología, Hospital Universitario Nacional de Colombia, Bogotá, Colombia.
In this article, we present an exceptionally rare and challenging clinical case. It concerns a 65-year-old woman who, while eating, accidentally ingested a thorn. This foreign body, after being swallowed, migrated from the proximal esophagus, until it penetrated the left internal jugular vein.
View Article and Find Full Text PDFEur Arch Otorhinolaryngol
January 2025
ENT Institute and Department of Otorhinolaryngology, Eye & ENT Hospital, Fudan University, Shanghai, 200031, China.
Objective: To evaluate the diagnostic potential of spontaneous otoacoustic emissions (SOAE), distortion product otoacoustic emissions (DPOAE), and pure-tone audiometry (PTA) in patients with pulsatile tinnitus (PT) caused by sigmoid sinus wall anomalies (SSWA).
Methods: This study included 20 PT patients and 20 matched healthy controls. SOAE, DPOAE, and PTA were assessed before and after compression of the internal jugular vein.
Plast Reconstr Surg Glob Open
January 2025
Division of Plastic and Reconstructive Surgery, University of Texas Health Science Center San Antonio, San Antonio, TX.
When squamous cell carcinoma necessitates mandibular resection, the resultant defect can be complex. An osteocutaneous fibula free flap is an effective reconstruction option, typically supplied by the peroneal artery for both the fibula and skin flap. In this case report, an anatomical variation was found: the skin paddle was supplied by soleus musculocutaneous perforators of the posterior tibial artery, whereas the fibula was supplied by the peroneal artery.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!