Background: The entirely subcutaneous implantable cardioverter defibrillator (S-ICD) was introduced as a new alternative to conventional transvenous ICD (TV-ICD) in Japan in February 2016, but its safety and efficacy are unclear.

Methods and results: A total of 60 patients (48 men, median age, 60 years; IQR, 44-67 years; primary prevention, n=24) underwent S-ICD implantation between February 2016 and August 2017. The device pocket was formed in the intermuscular space between the serratus anterior muscle and the latissimus dorsi muscle, and the parasternal S-ICD lead was placed according to pre-implant screening. Defibrillation test was performed in 56 patients (93%). Ventricular fibrillation (VF) was induced in 55 patients and terminated by a single 65-J shock in all patients. The median time to shock therapy was 13.4 s (IQR, 12.1-14.9 s) and the median post-shock impedance of the S-ICD lead was 64 Ω (IQR, 58-77 Ω). There were no operation-related complications or subsequent infectious complications. During follow-up (median, 275 days; IQR, 107-421 days), 1 patient (1.7%) had appropriate shock for VF with successful termination, whereas 5 patients (8.3%) had inappropriate shock due to oversensing of myopotential (n=3) or T-wave (n=1), and detection of supraventricular tachycardia (n=1).

Conclusions: S-ICD is a safe and effective alternative to conventional TV-ICD. The long-term safety and efficacy of the S-ICD need further investigation.

Download full-text PDF

Source
http://dx.doi.org/10.1253/circj.CJ-17-1001DOI Listing

Publication Analysis

Top Keywords

safety efficacy
12
cardioverter defibrillator
8
alternative conventional
8
february 2016
8
s-icd lead
8
patients
6
s-icd
6
efficacy subcutaneous
4
subcutaneous cardioverter
4
defibrillator patients
4

Similar Publications

Background: Due to the heterogeneity of literature findings, stent type selection for the endovascular treatment of complex aorto-iliac occlusive disease remains challenging. The BELSTREAM study, a physician-initiated, prospective, multicenter, single-arm study, aims to report the safety and efficacy of the balloon expandable LifeStream Peripheral Stent Graft System (BD, Tempe, Arizona, USA) for the treatment of complex TASC C and D aorto-iliac artery lesions.

Methods: Seventy patients and 133 lesions were included at six Belgian institutions.

View Article and Find Full Text PDF

Background: Poor acute postoperative pain control, coupled with the use of intravenous medications with a limited and unsafety efficacy spectrum, has led to new therapeutic alternative explorations to reduce adverse events while increasing its analgesic efficacy. There cannabinoids have been proposed as a useful control agent in post-surgical pain. Nevertheless, to date, there is no solid evidence to evaluate them.

View Article and Find Full Text PDF

Background: Cabotegravir + rilpivirine (CAB + RPV) administered via intramuscular gluteal injections is the first complete long-acting regimen for maintaining human immunodeficiency virus type 1 (HIV-1) virologic suppression. We present substudy results on short-term repeat intramuscular CAB + RPV long-acting thigh injections in participants with ≥3 years of experience with gluteal administration during the ATLAS-2M study.

Methods: Substudy phases included screening, thigh injection (day 1-week 16), and return to gluteal injection (week 16-week 24).

View Article and Find Full Text PDF

Limited available evidence comparing DOACs with warfarin suggests efficacy and safety of DOACs for CVT. We aimed to evaluate whether a specific DOAC is preferred for the treatment of CVT. This retrospective cohort study included adult patients with CVTs between September 2018 and September 2022 treated with a DOAC.

View Article and Find Full Text PDF

Chlorin e6: a promising photosensitizer of anti-tumor and anti-inflammatory effects in PDT.

Nanomedicine (Lond)

January 2025

Jiangsu Key Laboratory of New Drug Research and Clinical Pharmacy, Xuzhou Medical University, Xuzhou, China.

Photodynamic therapy (PDT) involves the activation of photosensitizers (PSs) by visible laser light at the target site to catalyze the production of reactive oxygen species, resulting in tumor cell death and blood vessel closure. The efficacy of PDT depends on the PSs, the amount of oxygen, and the intensity of the excitation laser. PSs have been extensively researched, and great efforts have been made to develop an ideal photosensitizer.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!