The importance of oxygen in the winemaking process is widely known, as it affects the chemical aspects and therefore the organoleptic characteristics of the final product. Hence, it is evident the usefulness of a continuous and real-time measurements of the levels of oxygen in the various stages of the winemaking process, both for monitoring and for control. The WOW project (Deployment of WSAN technology for monitoring Oxygen in Wine products) has focused on the design and the development of an innovative device for monitoring the oxygen levels in wine. This system is based on the use of an optical fiber to measure the luminescent lifetime variation of a reference metal/porphyrin complex, which decays in presence of oxygen. The developed technology results in a high sensitivity and low cost sensor head that can be employed for measuring the dissolved oxygen levels at several points inside a wine fermentation or aging tank. This system can be complemented with dynamic modeling techniques to provide predictive behavior of the nutrient evolution in space and time given few sampled measuring points, for both process monitoring and control purposes. The experimental validation of the technology has been first performed in a controlled laboratory setup to attain calibration and study sensitivity with respect to different photo-luminescent compounds and alcoholic or non-alcoholic solutions, and then in an actual case study during a measurement campaign at a renown Italian winery.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5948562 | PMC |
http://dx.doi.org/10.3390/s18041130 | DOI Listing |
Water Sci Technol
January 2025
Center for Sustainable Development, College of Arts and Sciences, Qatar University, Doha 2713, Qatar.
This work focused on the biotreatment of wastewater and contaminated soil in a used oil recycling plant located in Bizerte. A continuous stirred tank reactor (CSTR) and a trickling filter (TF) were used to treat stripped and collected wastewater, respectively. The CSTR was started up and stabilized for 90 days.
View Article and Find Full Text PDFTurk J Emerg Med
January 2025
Department of Emergency Medicine, Travancore Medical College Hospital, Kollam, Kerala, India.
Introduction: The initial 24-h period following admission to a hospital holds profound significance for pediatric patients, representing a critical window where proactive interventions can substantially influence outcomes. We devised a simple triage system, pediatric simple triage score (PSTS), to see whether rapid triage of sick pediatric patients with fever can be done using the new triage system in the emergency department (ED) to predict hospital admission.
Methods: This was a prospective observational study, conducted at the department of emergency medicine of a tertiary care teaching hospital in southern India.
Indian J Crit Care Med
November 2024
Department of Anesthesiology Critical Care, All India Institute of Medical Sciences, Rishikesh, Uttarakhand, India.
Background: To estimate a correlation between change in lung ultrasound aeration score (LUSS) and mortality in patients with ventilator-associated pneumonia.
Materials And Methods: We conducted a prospective observational study in which lung ultrasound, the partial pressure of arterial oxygen to fraction of inspired oxygen ratio (PaO/FiO ratio), and static lung compliance were performed for five consecutive days since the diagnosis of ventilator-associated pneumonia (day 1-5) in a 20-bed multidisciplinary intensive care unit in at a tertiary care academic institute in Northern India. A hundred and seventeen ventilated patients were studied for the first 5 days after ventilator-associated pneumonia (VAP) development.
Nat Sci Sleep
January 2025
Sleep Center, Department of Geriatric Respiratory, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou, People's Republic of China.
Purpose: Approximately 30% of patients with sleep-disordered breathing (SDB) present with masked hypertension, primarily characterized by elevated nighttime blood pressure. This study aimed to develop a hypertension prediction model tailored for primary care physicians, utilizing simple, readily available predictors derived from type IV sleep monitoring devices.
Patients And Methods: Participants were recruited from communities in Guangdong Province, China, between April and May 2021.
Spectrochim Acta A Mol Biomol Spectrosc
January 2025
Key Laboratory of Spectral Imaging Technology, Xi'an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi'an 710119 China. Electronic address:
Non-optically active water quality parameters (NAWQPs) are essential for surface water quality assessments, although automated monitoring methods are time-consuming, include labor-intensive chemical pretreatment, and pose challenges for high spatiotemporal resolution monitoring. Advancements in spectroscopic techniques and machine learning may address these issues. We integrated ultraviolet-visible-near infrared absorption spectroscopy with physical-chemical measurements to predict total nitrogen (TN), dissolved oxygen (DO), and total phosphorus (TP) in the Yangtze River Basin, China.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!