Background: Hypoactive lifestyle contributes to the development of secondary complications and lower quality of life in wheelchair users. There is a need for objective and user-friendly physical activity monitors for wheelchair-dependent individuals in order to increase physical activity through self-monitoring, goal setting, and feedback provision.
Objective: To determine the validity of Activ8 Activity Monitors to 1) distinguish two classes of activities: independent wheelchair propulsion from other non-propulsive wheelchair-related activities 2) distinguish five wheelchair-related classes of activities differing by the movement intensity level: sitting in a wheelchair (hands may be moving but wheelchair remains stationary), maneuvering, and normal, high speed or assisted wheelchair propulsion.
Methods: Sixteen able-bodied individuals performed sixteen various standardized 60s-activities of daily living. Each participant was equipped with a set of two Activ8 Professional Activity Monitors, one at the right forearm and one at the right wheel. Task classification by the Active8 Monitors was validated using video recordings. For the overall agreement, sensitivity and positive predictive value, outcomes above 90% are considered excellent, between 70 and 90% good, and below 70% unsatisfactory.
Results: Division in two classes resulted in overall agreement of 82.1%, sensitivity of 77.7% and positive predictive value of 78.2%. 84.5% of total duration of all tasks was classified identically by Activ8 and based on the video material. Division in five classes resulted in overall agreement of 56.6%, sensitivity of 52.8% and positive predictive value of 51.9%. 59.8% of total duration of all tasks was classified identically by Activ8 and based on the video material.
Conclusions: Activ8 system proved to be suitable for distinguishing between active wheelchair propulsion and other non-propulsive wheelchair-related activities. The ability of the current system and algorithms to distinguish five various wheelchair-related activities is unsatisfactory.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5894999 | PMC |
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0194864 | PLOS |
Disabil Rehabil Assist Technol
January 2025
School of Physical and Occupational Therapy, McGill University, Montreal, QC, Canada.
This exploratory qualitative study examines the challenges faced by manual wheelchair (MWC) users and their clinicians, with a focus on mobility difficulties in both outdoor and indoor environments, as well as training priorities. The study involved semi-structured interviews with 18 clinicians and 25 MWC users from various rehabilitation centres. The interviews, lasting between 30 and 60 minutes, explored specific aspects of MWC use, including mobility challenges, training needs, and psychological factors.
View Article and Find Full Text PDFSci Rep
December 2024
Faculty of Sports and Exercise Science, Universiti Malaya, 50603, Kuala Lumpur, Malaysia.
Wheelchair propulsion is a fundamental skill in wheelchair sports, particularly in wheelchair tennis. To achieve optimal mobility during wheelchair athletic performance, it is essential to consider propulsion techniques. This study examines the effect of push frequency and stroke duration on wheelchair maneuverability, measured by velocity during propulsion, among wheelchair tennis athletes.
View Article and Find Full Text PDFDisabil Rehabil Assist Technol
November 2024
Department of Human Movement Sciences, Faculty of Behavioural and Movement Sciences, Vrije Universiteit Amsterdam, Amsterdam Movement Sciences, Amsterdam, The Netherlands.
The main aim of this study was to compare sitting pressure (peak pressure index (PPI) and peak pressure gradient (PPG)) between a daily wheelchair and fixed-frame handcycle, thereby assessing the effect of handcycle backrest angle, movement intensity and cushion type. Twenty able-bodied participants performed static and dynamic (two intensities) tests in a wheelchair and handcycle. A honeycomb wheelchair cushion and standard foam handcycle cushion were used.
View Article and Find Full Text PDFJ Rehabil Med
November 2024
School of Rehabilitation, Faculty of Medicine, Université de Montréal, Montréal, QC, Canada; Centre for Interdisciplinary Research in Rehabilitation of Greater Montreal (CRIR) - Centre Intégré Universitaire de Santé et Services Sociaux (CIUSSS) du Centre-Sud-de-l'Île-de-Montréal, Montréal, QC, Canada.
Respir Care
November 2024
The authors are affiliated with Istinye University, Faculty of Health Sciences, Physiotherapy and Rehabilitation Department, Istanbul, Turkey.
Background: Spinal cord injury (SCI) detrimentally impacts individuals' exercise capacity and respiratory parameters depending on sensory, motor, and autonomic dysfunctions. Regular physical activity (PA) positively impacts cardiovascular health and pulmonary function in these individuals. This study determined the relationship between PA and exercise capacity and respiratory parameters in individuals with SCI.