The desired use of the HPH Jr. is optimal due to the low priming volume; however, the lower rate of volume removal necessitates utilization of a larger hemofilter. Larger hemofilters carry a higher prime volume, which is impactful in the pediatric setting. Pediatric cardiac surgery patients under 18 kilograms requiring cardiopulmonary bypass were randomly assigned to one of two study groups. Group 1 (coated) contained an HPH Jr. hemofilter that was primed with the addition of 25% albumin and heparin. Group 2 (non-coated) contained an HPH Jr. hemofilter that was primed with only Normosol-R®. After cardioplegia delivery, zero balance ultrafiltration (ZBUF) was initiated and maintained for thirty consecutive minutes. The flow through the hemofilter was standardized at 70 ml/min and the vacuum applied to the effluent line was set at -150 mmHg. Effluent fluid removal was measured at the termination of thirty minutes and compared between the groups. Group comparisons between the coated vs non-coated hemofilter groups were assessed using two-sample t-tests or the Mann-Whitney U test, when appropriate. Forty-two patients were included in the analysis. There were 22 patients who had the non-coated hemofilter and 20 patients with a coated hemofilter. The differences between the two groups are illustrated in Table 1. There was a statistically significant higher ultrafiltration volume with the coated hemofilter group (p=0.008) (Figure 1). These results illustrate the improved efficiency of the HPH Jr. with the addition of 25% albumin and heparin during the priming process.

Download full-text PDF

Source
http://dx.doi.org/10.1177/0267659118764270DOI Listing

Publication Analysis

Top Keywords

hemofilter
8
groups group
8
contained hph
8
hph hemofilter
8
hemofilter primed
8
addition 25%
8
25% albumin
8
albumin heparin
8
non-coated hemofilter
8
coated hemofilter
8

Similar Publications

: Renal replacement therapy with an oXiris hemofilter may be helpful for patients with acute kidney injury in conjunction with sepsis and septic shock. The aim of this study was to assess the impact of an oXiris membrane on septic shock patients. : All renal replacement therapies with oXiris (Baxter, Deerfield, IL, USA) performed between January 2018 and August 2021 were retrospectively analyzed.

View Article and Find Full Text PDF

Background: Cytokine-adsorption therapy has garnered attention as a potential treatment for conditions such as sepsis, although supporting evidence remains limited. Consequently, its utilization is expected to vary significantly across regions. To date, no ecological studies have investigated this regional heterogeneity.

View Article and Find Full Text PDF

Sulbactam-durlobactam is approved for the treatment of hospital-acquired and ventilator-associated bacterial pneumonia caused by susceptible isolates of complex. Patients with serious infections may require support with continuous renal replacement therapy (CRRT), which presents challenges for optimal dosing of antibiotics. Sulbactam-durlobactam dosing regimens were derived for this population using an CRRT model and Monte Carlo simulation (MCS).

View Article and Find Full Text PDF

Dynamic CRRT Prescription for Complicated Critically Ill Patient: A Case Report.

Case Rep Crit Care

November 2024

Department of Health Sciences, Section of Anesthesiology, Intensive Care and Pain Medicine, University of Florence, Florence, Italy.

Continuous renal replacement therapies (CRRTs) and sequential extracorporeal blood purification (EBP) therapies can be used in patients with severe COVID-19 disease to support kidney failure and restore immune homeostasis. EBP prescription should be based on the patient's clinical needs and frequently re-evaluated during the intensive care unit (ICU) stay. Personalization of treatment at the bedside plays a fundamental role for patient recovery.

View Article and Find Full Text PDF

Patient monitoring in the perioperative setting can be challenging, especially when monitoring multiple patients simultaneously or managing dynamic situations that require movement around the operating room. We aimed to evaluate whether avatar-based patient monitoring, which presents vital signs in the form of changing colors, shapes and motion, improves remote vital sign recognition compared to conventional monitoring. We conducted a prospective, single-center, computer-based simulation study to evaluate how anesthesia providers recognize vital signs when using the Philips Visual Patient Avatar at different viewing distances (8 and 16 m) compared to conventional monitoring.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?