Objectives: In rodents, we reported that short pulse-width (PW) neuromodulation might provide more efficient therapy delivery than traditional 0.21 msec PW. Using fully implanted, commercialized systems in the sheep, the goal of this study was to characterize the relationship of electromyographic (EMG) responses of the external anal sphincter (EAS) to different PWs of sacral neuromodulation (SNM).
Materials And Methods: In seven sheep, InterStim® quadripolar tined leads were implanted adjacent to the S3 nerve root bilaterally to deliver SNM and two pairs of intramuscular leads were placed on either side of the EAS for EMG sensing. The EMG responses to SNM with different PWs were examined using variable intensities in both anesthetized and conscious conditions.
Results: The EMG responses from ipsilateral EAS (I ) and contralateral EAS (C ) were compared. The area under the curve of EMG responses from I were significantly stronger than that from C The late component EMGs were more sensitive to nerve stimulation with a higher response amplitude in awake sheep. The response threshold-PW relationship from the I as ascertained visually and with EMG in anesthetized and awake sheep were fitted with a monoexponential nonlinear regression; the resulting chronaxies were of 0.05 msec (n = 6), and 0.04 msec (n = 6), and 0.04 msec (n = 8), respectively.
Conclusions: In both anesthetized and awake conditions, a similar motor response may be evoked in the EAS at PWs much shorter (0.04-0.05 msec) than the 0.21 msec typically used with SNM. Potential battery savings manifested by shorter PW would provide more efficient therapy delivery and increased longevity of the stimulator.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/ner.12779 | DOI Listing |
Sensors (Basel)
December 2024
Department of Robotics and Mechatronics, Tokyo Denki University, Tokyo 120-8551, Japan.
As robots become increasingly integrated into human society, the importance of human-machine interfaces continues to grow. This study proposes a faster and more accurate control system for myoelectric prostheses by considering the Electromechanical Delay (EMD), a key characteristic of Electromyography (EMG) signals. Previous studies have focused on systems designed for wrist movements without attempting implementation.
View Article and Find Full Text PDFSensors (Basel)
December 2024
College of Material Science and Technology, Beijing Forestry University, Beijing 100083, China.
Mattress firmness is a critical factor influencing sleep quality. This study investigates the effects of time, mattress firmness, and anthropometric parameters on surface electromyographic (sEMG) activity during supine rest. Eleven participants were analyzed, and the values for lower back sEMG on three mattresses were measured as 8.
View Article and Find Full Text PDFPolymers (Basel)
December 2024
Chongqing Academy of Metrology and Quality Inspection, Chongqing 401120, China.
Dynamic hydrogels have attracted considerable attention in the application of flexible electronics, as they possess injectable and self-healing abilities. However, it is still a challenge to combine high conductivity and antibacterial properties into dynamic hydrogels. In this work, we fabricated a type of dynamic hydrogel based on acylhydrazone bonds between thermo-responsive copolymer and silver nanoparticles (AgNPs) functionalized with hydrazide groups.
View Article and Find Full Text PDFBMC Sports Sci Med Rehabil
January 2025
Universite Lyon 1, Laboratoire Interuniversitaire de Biologie de la Motricité - UR 7424, UFRSTAPS, Villeurbanne, France.
Background: The Closed Kinetic Chain Upper Extremity Stability Test (CKCUEST) is a physical performance test designed to assess the upper extremity (UE) stability. However, only one outcome measure is provided for both UEs, limiting its application if the UEs are not similarly involved. Moreover, the changes in loads sustained by the support UE throughout the movement may influence the support UE stability.
View Article and Find Full Text PDFJ Voice
January 2025
Department of Otolaryngology-Head and Neck Surgery, UCSF Voice and Swallowing Center, UCSF School of Medicine, San Francisco, CA. Electronic address:
Background: Laryngeal respiratory dystonia (LRD) is diagnosed based on clinical presentation, patient history, and physical examination. Key indicators include dyspnea, desynchronized breathing patterns, and laryngoscopic findings that reveal vocal fold adduction during inspiration. Treatment for LRD remains controversial and often yields limited effectiveness.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!