A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

High volume of polysorbate-containing (Tween 80) solutions induces false-positive results in intradermal test. | LitMetric

High volume of polysorbate-containing (Tween 80) solutions induces false-positive results in intradermal test.

J Eur Acad Dermatol Venereol

Department of Dermatology, Clinical Centre Darmstadt, Darmstadt, Germany.

Published: November 2018

Background: Intradermal test is used to detect causative allergens in IgE-mediated hypersensitivity. The surfactant polysorbate 80 can be added to intradermal test solutions to more reliably dissolve the allergen and ensure a constant bioavailability of the injected allergen. Polysorbate 80 has, however, some histamine-releasing properties which could blur the difference to the histamine-induced wheal. Routinely serving as a control.

Objective: Allergen-free polysorbate 80 containing (0.005%) test solutions were therefore systematically tested at different injection volumes to see whether polysorbate can falsify skin reactions and if yes whether conditions can be identified to avoid this.

Methods: In a partly blinded study, 30 patients were tested intracutaneously at the back: each received at three separate sites 0.05 mL of polysorbate-containing solvent, 0.02 mL polysorbate-containing solvent as well as 0.02 mL polysorbate-free solvent. After 15 min, wheal and erythema were documented and planimetrically quantified.

Results: Unexpectedly 23 of 30 (77%) patients showed false-positive test reactions to the volume of 0.05 mL of the polysorbate-containing solvent whereas the polysorbate-containing solvent with 0.02 mL and the polysorbate-free solvent with 0.02 mL injection volume had no reinforcing effect on skin test reaction.

Conclusions: Different volumes of polysorbate-containing solutions, all recommended by manufacturers for intradermal tests, may significantly influence test results. The study shows that a polysorbate 80 used at 0.005% in solvents for intradermal test to provide a better bioavailability of allergens produces false-positive reactivity in a surprising and a hitherto unknown 77% if the 0.05 mL volume is injected. It is, therefore, mandatory to strictly adhere to an intradermal test volume of 0.02 mL as only then falsifying effects of the polysorbate additive are avoided, and comparable test results are ensured.

Download full-text PDF

Source
http://dx.doi.org/10.1111/jdv.14999DOI Listing

Publication Analysis

Top Keywords

intradermal test
20
polysorbate-containing solvent
16
solvent 002
12
test
10
test solutions
8
polysorbate 0005%
8
005 polysorbate-containing
8
002 polysorbate-free
8
polysorbate-free solvent
8
polysorbate-containing
6