Purpose: Pedicle screw malplacement, leading to neurological symptoms, vascular injury, and premature implant loosening, is not uncommon and difficult to reliably detect intraoperatively with current techniques. We propose a new intraoperative post-placement pedicle screw position assessment system that can therefore allow surgeons to correct breaches during the procedure. Our objectives were to assess the accuracy and robustness of this proposed screw location system and to compare its performance to that of 2D planar radiography.
Methods: The proposed system uses two intraoperative X-ray shots acquired with a standard fluoroscopic C-arm and processed using 2D/3D registration methods to provide a 3D visualization of the vertebra and screw superimposed on one another. Point digitization and CT imaging of the residual screw tunnel were used to assess accuracy in five synthetic lumbar vertebral models (10 screws in total). Additionally, the accuracy was evaluated with and without correcting for image distortion and for various screw lengths, screw materials, breach directions, and vertebral levels.
Results: The proposed method is capable of localizing the implanted screws with less than 2 mm of translational error (RMSE: 0.7 and 0.8 mm for the screw head and tip, respectively) and less than [Formula: see text] angular error (RMSE: [Formula: see text]), with minimal change to the errors if image distortion is not corrected. Breaches and their anatomical locations were all correctly visualized and identified for a variety of screw lengths, screw materials, breach locations, and vertebral levels, demonstrating the robustness of this approach. In contrast, one breach, one non-breach, and the anatomical location of three screws were misclassified with 2D X-ray.
Conclusion: We have demonstrated an accurate and low-radiation technique for localizing pedicle screws post-implantation that requires only two X-rays. This intraoperative feedback of screw location and direction may allow the surgeon to correct malplaced screws intraoperatively, thereby reducing postoperative complications and reoperation rates.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s11548-018-1732-8 | DOI Listing |
Sci Rep
January 2025
Department of Orthopaedic, South China Hospital of Shenzhen University, Shenzhen, 518116, Guangdong, China.
Before patients begin out-of-bed exercises following internal fixation surgery for acetabular fractures, turning over in bed serves as a crucial intervention to mitigate complications associated with prolonged bed rest. However, data on the safety of this maneuver post-surgery are limited, and the biomechanical evidence remains unclear. This study aims to introduce a novel loading protocol designed to preliminarily simulate the action of turning over in bed and to compare the biomechanical properties of two fixation methods for acetabular fractures under this new protocol.
View Article and Find Full Text PDFSci Rep
January 2025
College of Medicine, Mohammed Bin Rashid University of Medicine and Health Sciences, Dubai Health, Dubai, UAE.
The first cervical vertebra (C1) is atypical in shape and bears a complex relationship with important neurovascular structures such as the vertebral artery and cervical spinal cord which are at risk of injury during misplaced screw fixation of C1. Placement of screws into the lateral mass of C1 vertebra is performed for stabilization of the craniovertebral junction. The objective of this study was to describe ideal screw dimensions, precise entry points, safe bony corridors, and ideal trajectories for placement of lateral mass screws in the Emirati population.
View Article and Find Full Text PDFWorld Neurosurg
January 2025
Department of Endocrinology, Yinzhou No.2 Hospital, Ningbo, Zhejiang 315040, China. Electronic address:
Objective: This study aims to evaluate the clinical outcomes of utilizing C1 posterior arch screws (PAS) combined with C2 translaminar screws as an adjunct for reinforcing upper cervical spine fixation.
Methods: A retrospective analysis was conducted on four male patients who underwent surgery involving C1 PASs and C2 translaminar screws between January 2022 and February 2024. Surgical technique involved the insertion of standard C1 lateral mass screws (LMS) and C2 pedicle screws, followed by the placement of C1 PASs and C2 translaminar screws for additional fixation.
Handchir Mikrochir Plast Chir
January 2025
Hand Surgery, Baltalimani Special Hospital for Bone Diseases, Istanbul, Turkey.
Purpose: This study aims to compare the clinical and radiological outcomes of three different techniques used in the surgical treatment of ulnar styloid fractures.
Material And Method: Ulnar styloid fractures treated surgically between 2012 and 2022 were evaluated retrospectively. There were three groups in the study: Group I (Kirschner wire, N= 19), Group II (tension band, N= 27) and Group III (headless compression screw, N= 25).
Int J Surg Case Rep
January 2025
Department of Neurosurgery, Damascus Hospital, Damascus, Syria; Faculty Of Medicine, Al-fourat university, Deir ez-Zor, Syria.
Introduction And Clinical Importance: Giant cell tumor (GCT) is a rare benign bone tumor that usually affects skeletally adult people. While it usually appears in the epiphyseal parts of long bones, it is very rare in the spine, particularly the thoracic spine, especially in pediatric patients.
Case Presentation: An 11-year-old female presented with progressive lower extremity weakness, accompanied by localized back pain and urinary urgency, diagnosed with GCT in the thoracic spine.