Background: Scarce reports exist of permanent deployment of Solitaire FR™ devices for arterial steno-occlusive disease as it is primarily indicated for temporary deployment for thrombectomy in large-vessel, anterior-circulation ischemic strokes. Even more scarce are reports describing permanent deployment of the Solitaire device for posterior circulation strokes.
Summary: We present 2 cases where the Solitaire device was electrolytically detached to re-establish flow in an occluded or stenotic basilar artery in acutely symptomatic patients. In both cases, a 4 × 15 mm Solitaire device was positioned across the stenotic or occluded portion of the basilar artery and electrolytically detached to maintain vessel patency. Both cases had good clinical outcomes with a National Institutes of Health Stroke Scale (NIHSS) score of 1 (from 24) on 90-day follow-up and an NIHSS score of 2 (from 7) on 30-day follow-up.
Key Messages: Permanent deployment of the Solitaire device may potentially be a safe and effective means of maintaining vessel patency in an occluded or stenotic basilar artery.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5881145 | PMC |
http://dx.doi.org/10.1159/000480245 | DOI Listing |
J Cardiothorac Surg
December 2024
Department of Cardiology, Thomas Jefferson University, Philadelphia, PA, 19107, USA.
Background: Right ventricular (RV) function assessment by echocardiography can be challenging due to its complex morphology. Also, increasing use of sedation rather than general anesthesia for transfemoral approach transcatheter aortic valve replacement (TAVR) reduces the need for intraoperative transesophageal echocardiography (TEE). Recent clinical studies have demonstrated the importance of 3-dimensional (3D) echocardiography and a longitudinal strain for RV function assessment.
View Article and Find Full Text PDFJ Cardiovasc Dev Dis
December 2024
Faculty of Medicine & Health Sciences, University of Antwerp, 2610 Antwerp, Belgium.
The need for a permanent pacemaker (PPM) implantation after surgical aortic valve implantation (SAVR) is a recognized postoperative complication, with potentially long-term reduced survival. From 1987 to 2017, 2500 consecutive patients underwent SAVR with a biological valve with or without concomitant procedures such as CABG or mitral valve repair. Mechanical valves or valves in another position were excluded.
View Article and Find Full Text PDFHeliyon
November 2024
Collaborative Innovation Center for Performance and Security of Large-scale Infrastructure, Shijiazhuang Tiedao University, Shijiazhuang, China.
Ann Work Expo Health
November 2024
Division of Preventive Medicine, University of Alberta, 8303 112 St, Edmonton, Alberta, T6G 2T4, Canada.
We introduce bia-binder (BioImage Archive Binder), an open-source, cloud-architectured, and web-based coding environment tailored to bioimage analysis that is freely accessible to all researchers. The service generates easy-to-use Jupyter Notebook coding environments hosted on EMBL-EBI's Embassy Cloud, which provides significant computational resources. The bia-binder architecture is free, open-source and publicly available for deployment.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!