Introduction: The rotating hinge prosthesis was originally used and designed as a primary total knee arthroplasty implant, but was hampered due to poor outcomes and catastrophic failures. Newer rotating hinge implants can be utilized in complex revision total knee arthroplasties when appropriately indicated, but their outcome data is very difficult to interpret due to the strict and varied indications for use and subsequently small number of procedures performed. The goal of this review is to evaluate the current evidence on large cohort, rotating hinge knee prostheses used in the revision setting, in order to provide a clearer understanding of the indications, outcomes and complications.
Methods: The PubMed database was utilized to search the available literature regarding "hinged knee," or "rotating hinge" devices. Exclusion criteria included papers focusing on primary arthroplasty, revision for oncologic issues, one-stage revision for infection or studies with less than fifty cases.
Results: Review of 115 abstracts after initial search, led to ten studies in the literature that met our inclusion and exclusion criteria. The data shows that rotating hinge knee implants have good survivorship ranging from 51% to 92.5% at 10 years post-operatively. Complication rates range from 9.2% to 63% with infection and aseptic loosening as the most common complications.
Conclusion: Rotating hinge knee prostheses are most commonly indicated for infection, aseptic loosening, instability and bone loss in the literature. They have good outcome scores and survivorship, but continue to have high complication and revision rates. The implant is a good option when utilized appropriately for patients that are not candidates for less constrained devices.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5884045 | PMC |
http://dx.doi.org/10.1016/j.jcot.2017.11.020 | DOI Listing |
Sci Rep
December 2024
College of Information Engineering, SuQian University, SuQian, 223800, China.
The safety and reliability of rotating machinery hinge significantly on the proper functioning of rolling bearings. In the last few years, there have been significant advances in the algorithms for intelligent fault diagnosis of bearings. However, the vibration signals collected by machines are inevitably affected by irrelevant noise because of the complex working environments of bearings.
View Article and Find Full Text PDFAnat Rec (Hoboken)
December 2024
Biology Department, Northland Pioneer College, Holbrook, Arizona, USA.
Nothronychus graffami was a large therizinosaur represented by a single well-preserved individual from the Turonian Tropic Shale of southern Utah. It is characterized by an enlarged abdomen, small tail, and an extensively pneumatized axial skeleton, and is frequently regarded as herbivorous. Given the overall tail reduction and the development of a wide fused synsacrum with widely spaced acetabulae, it is reconstructed with an anteriorly rotated femur and a displaced resting ground reaction force anterior to the center of mass.
View Article and Find Full Text PDFBMC Musculoskelet Disord
December 2024
Department of Orthopedics Surgery, Shandong Provincial Hospital affiliated to Shandong First Medical University, 324 Jing Wu Road, Jinan, 250021, China.
Background: The present study aimed to compare the functional outcomes of hinged external fixators and non-external fixation in open elbow arthrolysis (OEA) for post-traumatic elbow stiffness (PTES) and to evaluate their applicability and limitations in patients with posttraumatic elbow stiffness.
Methods: The clinical data of patients with PTES treated with OEA at our hospital between March 2015 and June 2022 were retrospectively analyzed. The assessed variables were the operation time, intraoperative blood loss volume, duration of hospitalization, and treatment costs.
Knee Surg Sports Traumatol Arthrosc
December 2024
Department of Trauma, Hand and Reconstructive Surgery, University Hospital Münster, Münster, Germany.
Purpose: To investigate the biomechanical consequences of osteosynthesis of lateral hinge fractures (LHFs) in medial open wedge high tibial osteotomy (MOWHTO).
Methods: Sixteen fresh-frozen human cadaveric proximal tibiae underwent MOWHTO fixed with an ipsilateral locking compression plate. The specimens were assigned to two clusters simulating LHFs according to the Takeuchi classification: (1) Type II fracture; and (2) Type III fracture.
J Arthroplasty
December 2024
Ankara City Hospital, Department of Orthopedics and Traumatology, Ankara, TURKEY.
Background: Rotating hinge knee arthroplasty (RHKA) implants are often utilized as a salvage procedure in cases where bone stock is compromised. The aim of this retrospective study was to investigate whether residual collateral ligament integrity affects functional and radiographic outcomes in patients undergoing revision surgery with RHKA.
Methods: Patients treated with RHKA between 2011 and 2021 were eligible.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!