A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

New alternate bearing surfaces in total hip arthroplasty: A review of the current literature. | LitMetric

New alternate bearing surfaces in total hip arthroplasty: A review of the current literature.

J Clin Orthop Trauma

Department of Orthopaedic Surgery, State University of New York, Downstate Medical Center, Brooklyn, NY 11203, USA.

Published: October 2017

As indications for total hip arthroplasty (THA) have expanded, the incidence of THA has increased among younger patients, who live longer and tend to place more strain on implants via higher activity levels. This demographical shift accentuates the importance of advancing innovation to ensure implant longevity for younger and more active patients. Future innovation, as it pertains to THA components, is likely to focus on modifying implant designs and tribology in conjunction with identification and application of newer biomaterials. By reviewing the literature for development status of various materials and novel design advancements in THA component outside of the standard highly cross-linked polyethylene, this investigation provided an update on the current and future status of design initiatives as they pertain to THA. Though the highlighted alternative bearing surfaces have shown promising and limited, yet encouraging clinical data, they lack larger and longer-term clinical trial results. Further research and innovation is warranted to identify the optimal bearing surface to most effectively accommodate for the trend of younger and more active patients undergoing THA. Implant longevity is crucial if the clinical success of THA is to be maintained.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5884051PMC
http://dx.doi.org/10.1016/j.jcot.2017.10.013DOI Listing

Publication Analysis

Top Keywords

bearing surfaces
8
total hip
8
hip arthroplasty
8
implant longevity
8
younger active
8
active patients
8
tha
7
alternate bearing
4
surfaces total
4
arthroplasty review
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!