A green, simple and cost effective chemometric UV-Vis spectrophotometric method has been developed and validated for correcting interferences that arise during conducting biowaiver studies. Chemometric manipulation has been done for enhancing the results of direct absorbance, resulting from very low concentrations (high incidence of background noise interference) of earlier points in the dissolution timing in case of dissolution profile using first and second derivative (D1 & D2) methods and their corresponding Fourier function convoluted methods (D1/FF& D2/FF). The method applied for biowaiver study of Donepezil Hydrochloride (DH) as a representative model was done by comparing two different dosage forms containing 5mg DH per tablet as an application of a developed chemometric method for correcting interferences as well as for the assay and dissolution testing in its tablet dosage form. The results showed that first derivative technique can be used for enhancement of the data in case of low concentration range of DH (1-8μgmL) in the three different pH dissolution media which were used to estimate the low drug concentrations dissolved at the early points in the biowaiver study. Furthermore, the results showed similarity in phosphate buffer pH6.8 and dissimilarity in the other 2pH media. The method was validated according to ICH guidelines and USP monograph for both assays (HCl of pH1.2) and dissolution study in 3pH media (HCl of pH1.2, acetate buffer of pH4.5 and phosphate buffer of pH6.8). Finally, the assessment of the method greenness was done using two different assessment techniques: National Environmental Method Index label and Eco scale methods. Both techniques ascertained the greenness of the proposed method.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.saa.2018.03.059DOI Listing

Publication Analysis

Top Keywords

correcting interferences
12
method
8
method correcting
8
biowaiver studies
8
assay dissolution
8
study donepezil
8
donepezil hydrochloride
8
biowaiver study
8
phosphate buffer
8
buffer ph68
8

Similar Publications

The early prediction of Alzheimer's disease (AD) risk in healthy individuals remains a significant challenge. This study investigates the feasibility of task-state EEG signals for improving detection accuracy. Electroencephalogram (EEG) data were collected from the Multi-Source Interference Task (MSIT) and Sternberg Memory Task (STMT).

View Article and Find Full Text PDF

A pseudogene is a non-functional copy of a protein-coding gene. Processed pseudogenes, which are created by the reverse transcription of mRNA and subsequent integration of the resulting cDNA into the genome, being a major pseudogene class, represent a significant challenge in genome analysis due to their high sequence similarity to the parent genes and their frequent absence in the reference genome. This homology can lead to errors in variant identification, as sequences derived from processed pseudogenes can be incorrectly assigned to parental genes, complicating correct variant calling.

View Article and Find Full Text PDF

Problem: Hashimoto's disease is the commonest autoimmune disease of pregnancy. The presence of Anti-Thyroid antibodies (ATAs) alone [subclinical hypothyroidism] has also been shown to have adverse pregnancy effects. These can result in failure to conceive, recurrent miscarriages, anemia, preeclampsia, and abruption.

View Article and Find Full Text PDF

Background: Functional near-infrared spectroscopy (fNIRS) is being increasingly utilized to visualize the brain areas involved in cognitive activity to understand the human brain better. Its portability and easy setup give it an advantage over other functional brain imaging tools. The current study utilizes fNIRS while performing a Stroop test, which is commonly used to assess the impairment of information selection in depression.

View Article and Find Full Text PDF

The integration of radar technology into smart furniture represents a practical approach to health monitoring, circumventing the concerns regarding user convenience and privacy often encountered by conventional smart home systems. Radar technology's inherent non-contact methodology, privacy-preserving features, adaptability to diverse environmental conditions, and high precision characteristics collectively establish it a compelling alternative for comprehensive health monitoring within domestic environments. In this paper, we introduce a millimeter (mm)-wave radar system positioned strategically behind a seat, featuring an algorithm capable of identifying unique cardiac waveform patterns for healthy subjects.

View Article and Find Full Text PDF