Efficacy and safety of baroreflex activation therapy for treatment of resistant hypertension: a systematic review and meta-analysis.

Clin Exp Hypertens

a Department of Cardiology , The Second Affiliated Hospital of Chongqing Medical University, The Third People's Hospital of Chengdu, Chongqing , Sichuan , China.

Published: October 2018

To provide definite evidence for the anti-hypertensive benefit of Baroreflex Activation Therapy (BAT) for resistant hypertension, we performed a systematic review and meta-analysis to evaluate the efficacy and safety of BAT. Electronic searches were conducted in PubMed, EMBASE, The Cochrane Library and Web of Science. Two reviewers independently determined the eligibility of studies and extracted the data. The quality of all included studies was evaluated by the use of the Newcastle Ottawa Scale (NOS). Disagreements were settled through discussion. Twelve studies, included one randomized clinical trials (RCTs) and eleven prospective studies were eligible for qualitative analysis and five prospective studies were selected for meta-analysis. The data of analysis showed office systolic blood pressure (SBP)(WMD = -24.01, 95% CI = -28.65 to -19.36, P= 0.753I = 0.0%) and diastolic blood pressure (DBP)(WMD = -12.53, 95% CI = -15.82 to -9.24,P = 0.893,I = 0.893) decreased by BAT treatment.The effect on SBP was both significant in the Barostim neo TM device (WMD = -22.49, 95% CI = -29.13 to 15.84, P= 0.443; I = 0.0%) and Rheos System (WMD = 25.46, 95% CI = -31.96 to -18.96, P= 0.703; I = 0.0%). Our study found office BP were significantly decreased by BAT treatment, but available evidence is limited by risk of bias, small sample size, and few RCTs. Thus, there is presently insufficient evidence to fully evaluate the efficacy and safety of BAT for Patients with Resistant Hypertension. Additional high-quality RCT research with long-term follow-up is required.

Download full-text PDF

Source
http://dx.doi.org/10.1080/10641963.2016.1273943DOI Listing

Publication Analysis

Top Keywords

efficacy safety
12
resistant hypertension
12
baroreflex activation
8
activation therapy
8
systematic review
8
review meta-analysis
8
evaluate efficacy
8
safety bat
8
prospective studies
8
blood pressure
8

Similar Publications

Background: Liver malignancies present substantial challenges to surgeons due to the extensive hepatic resections required, frequently resulting in posthepatectomy liver failure. Associating liver partition and portal vein ligation for staged hepatectomy (ALPPS) was designed to increase the resectable liver volume, yet it is associated with significant mortality and morbidity rates. Recently, minimally invasive techniques have been incorporated into ALPPS, with the potential to improve the procedure's safety profile whilst maintaining efficacy.

View Article and Find Full Text PDF

The widespread adoption of high-resolution computed tomography (CT) screening has led to increased detection of small pulmonary nodules, necessitating accurate localization techniques for surgical resection. This review examines the evolution, efficacy, and safety of various localization methods for small pulmonary nodules. Studies focusing on localization techniques for pulmonary nodules ≤30 mm in diameter were included, with emphasis on technical success rates and complication profiles.

View Article and Find Full Text PDF

Vibriosis caused by Vibrio anguillarum has been an important bacterial disease in cultured rainbow trout (Oncorhynchus mykiss). In the present study, we evaluated the protective efficacy of a vaccine that consists of formalin-killed (FK) V. anguillarum and the alr genes knockout auxotrophic-live (AL) V.

View Article and Find Full Text PDF

Background And Aim: Although long self-expandable metal stent (SEMS) with a sufficient intragastric portion is typically preferred for endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS), this design can complicate endoscopic re-intervention for recurrent biliary obstruction (RBO). We evaluated the efficacy and safety of endoscopic re-intervention for RBO through the stent after EUS-HGS using a novel partially covered SEMS with an anchoring flange.

Methods: The partially covered SEMS was designed with a intrahepatic uncovered portion measuring 1.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!