Building Ultrasound Phantoms With Modified Polyvinyl Chloride: A Comparison of Needle Insertion Forces and Sonographic Appearance With Commercial and Traditional Simulation Materials.

Simul Healthc

From the Department of Mechanical and Nuclear Engineering (D.F.P.), College of Medicine Department of Surgery (C.C.S., D.C.H.), School of Engineering Design, Technology, and Professional Programs (R.S.P.), Department of Industrial and Manufacturing Engineering (M.A.Y.), Department of Engineering Design and Industrial Engineering (S.R.M.), Department of Mechanical and Nuclear Engineering (J.Z.M.), The Pennsylvania State University, State College, PA.

Published: June 2018

Introduction: Training using ultrasound phantoms allows for safe introduction to clinical skills and is associated with improved in-hospital performance. Many materials have been used to simulate human tissue in phantoms including commercial manikins, agar, gelatin, and Ballistics Gel; however, phantom tissues could be improved to provide higher-fidelity ultrasound images or tactile sensation. This article describes a novel phantom tissue mixture of a modified polyvinyl chloride (PVC) polymer, mineral oil, and chalk powder and evaluates needle cutting and ultrasonic properties of the modified PVC polymer mixture compared with a variety of phantom tissues.

Methods: The first experiment measured axial needle forces of a needle insertion into nine phantom materials, including three formulations of modified PVC. The second experiment used a pairwise comparison survey of ultrasound images to determine the perceived realism of phantom ultrasound images.

Results: It was found that the materials of Ballistics Gel and one of the PVC mixtures provide stiff force feedback similar to cadaver tissue. Other phantom materials including agar and gelatin provide very weak unrealistic force feedback. The survey results showed the PVC mixtures being viewed as the most realistic by the survey participants, whereas agar and Ballistics Gel were seen as the least realistic.

Conclusions: The realism in cutting force and ultrasound visualization was determined for a variety of phantom materials. Novel modified PVC polymer has great potential for use in ultrasound phantoms because of its realistic ultrasound imaging and modifiable stiffness. This customizability allows for easy creation of multilayer tissue phantoms.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5986593PMC
http://dx.doi.org/10.1097/SIH.0000000000000302DOI Listing

Publication Analysis

Top Keywords

ultrasound phantoms
12
ballistics gel
12
pvc polymer
12
modified pvc
12
phantom materials
12
modified polyvinyl
8
polyvinyl chloride
8
needle insertion
8
tissue phantoms
8
agar gelatin
8

Similar Publications

Introduction: Ultrasound-guided regional anaesthesia enhances pain control, patient outcomes and lowers healthcare costs. However, teaching this skill effectively presents challenges with current training methods. Simulation-based medical education offers advantages over traditional methods.

View Article and Find Full Text PDF

Fourier energy spectrum centroid: a robust and efficient approach for shear wave speed estimation in ω-K space.

Phys Med Biol

January 2025

Department of Electrical and Electronic Engineering, The University of Hong Kong, Chow Yei Ching 506, Hong Kong, 999077, HONG KONG.

. The propagation speed of a shear wave, whether externally or internally induced, in biological tissues is directly linked to the tissue's stiffness. The group shear wave speed (SWS) can be estimated using a class of time-of-flight (TOF) methods in the time-domain or phase speed-based methods in the frequency domain.

View Article and Find Full Text PDF

Blood pressure (BP) is one of the vital physiological parameters, and its measurement is done routinely for almost all patients who visit hospitals. Cuffless BP measurement has been of great research interest over the last few years. In this paper, we aim to establish a method for cuffless measurement of BP using ultrasound.

View Article and Find Full Text PDF

Dual-Modality Flow Phantom for Ultrasound and Optical Flow Measurements.

Phys Med Biol

January 2025

Schlegel Research Institute for Aging, University of Waterloo, 250 Laurelwood Drive, Waterloo, Ontario, N2L 3G1, CANADA.

As ultrasound-compatible flow phantoms are devised for performance testing and calibration, there is a practical need to obtain independent flow measurements for validation using a gold-standard technique such as particle image velocimetry (PIV). In this paper, we present the design of a new dual-modality flow phantom that allows ultrasound and PIV measurements to be simultaneously performed. Our phantom's tissue mimicking material is based on a novel hydrogel formula that uses propylene glycol to lower the freezing temperature of an ultrasound-compatible poly(vinyl) alcohol cryogel and, in turn, maintain the solution's optical transparency after thermocycling.

View Article and Find Full Text PDF

Current study presents an advanced method for improving the visualization of subsurface blood vessels using laser speckle contrast imaging (LSCI), enhanced through principal component analysis (PCA) filtering. By combining LSCI and laser speckle entropy imaging with PCA filtering, the method effectively separates static and dynamic components of the speckle signal, significantly improving the accuracy of blood flow assessments, even in the presence of static scattering layers located above and below the vessel. Experiments conducted on optical phantoms, with the vessel depths ranging from 0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!