Objectives: To evaluate the technical feasibility of direct Eustachian tube catheterisation and subtraction Eustachian tubography in a cadaver model.
Methods: A total of 12 separate sessions were performed on both sides of the Eustachian tube (ET) in six human cadavers. Cadavers were positioned for the submentovertical view on a fluoroscopy table. Endoscopy-guided ET selection was used in the first three cadavers, whereas fluoroscopy-guided ET selection was used in the remaining three. Eustachian tubography was performed by injecting 2 ml of contrast media through a 5-Fr catheter. We recorded the success of ET selection, number of attempts, procedure time, and tubography quality using native and subtraction images (range, 0-3).
Results: Both endoscopy- and fluoroscopy-guided selections were successfully performed in five of six sessions (83.3%). There were no statistically significant differences between the endoscopy- and fluoroscopy-guided procedures in terms of the number of attempts, procedure time, rate of immediate contrast leak to the middle ear cavity, and quality of tubography (p > 0.05). An excellent quality of tubography was obtained in 83.3% (10 of 12 sessions) of subtraction images and in 33.3% (4 of 12 sessions) of native images. The tubography quality score was significantly higher for the subtraction images than for the native images (p = 0.04).
Conclusion: Subtraction Eustachian tubography using direct catheterisation seems to be technically feasible. The entire ET can be well visualised; thus, this technique can be used as a simple tool for assessment of ET function and anatomy.
Key Points: • Direct catheterisation of the Eustachian tube is technically feasible. • The entire Eustachian tube could be well visualised by direct Eustachian tubography. • Subtraction Eustachian tubography images have better image quality than native images. • Subtraction Eustachian tubography can provide objective assessment of ET function and anatomy.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00330-018-5392-4 | DOI Listing |
J Interv Med
February 2023
Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 388-1, Poongnap 2-dong, Songpa-gu, Seoul, 05505, Republic of Korea.
Purpose: This study investigated the anatomical and histological characteristics of the rat Eustachian tube (E-tube) and the feasibility of Eustachian tubography in a rat model.
Materials And Methods: Fifteen male Wistar rats were used in this study, and the bilateral E-tubes of each rat were examined. Ten E-tubes were used for anatomical studies, another ten for histological analysis, and the other ten for Eustachian tubography.
Background: Not many imaging techniques have been reported in Eustachian tube imaging.
Purpose: To investigate the role of selective Eustachian tubography (SET) and Valsalva computed tomography (CT) in patients who underwent Eustachian tube balloon dilation (ETBD).
Material And Methods: Eligible patients were aged 18 years and older with chronic Eustachian tube dysfunction who had failed medical treatment.
J Vasc Interv Radiol
August 2018
Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 88, Olympic-ro 43-gil, Songpa-gu, Seoul, 05505, Republic of Korea. Electronic address:
Purpose: To investigate the technical feasibility of stent placement in the cartilaginous portion of the Eustachian tube (ET).
Materials And Methods: Twelve ETs of 6 cadavers were used. Two different-sized stents were placed on either the right (2.
Eur Radiol
September 2018
Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 88, Olympic-ro 43-gil, Songpa-gu, Seoul, 138-736, Republic of Korea.
Objectives: To evaluate the technical feasibility of direct Eustachian tube catheterisation and subtraction Eustachian tubography in a cadaver model.
Methods: A total of 12 separate sessions were performed on both sides of the Eustachian tube (ET) in six human cadavers. Cadavers were positioned for the submentovertical view on a fluoroscopy table.
AJR Am J Roentgenol
April 1995
Department of Radiology, Children's Hospital, Boston, MA 02115, USA.
As young radiologists read the slightly self-satisfied articles celebrating the centennial of radiology, they may conclude that the course of radiology and all its components has been smoothly upward, without hesitations, false starts, or disappointments. Older radiologists know better. The replacement of a less satisfactory technique with a better one is a gain for both patients and physicians, but the replacement process itself can be distressing.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!