Epidemiological investigation is an important approach to assessing the risk of late effects after radiotherapy, and organ dosimetry is a crucial part of such analysis. Computed tomography (CT) images, if available, can be a valuable resource for individualizing the dosimetry, because they describe the specific anatomy of the patient. However, CT images acquired for radiation treatment planning purposes cover only a portion of the body near the target volume, whereas for epidemiology, the interest lies in the more distant normal tissues, which may be located outside the scan range. To address this challenge, we developed a novel method, called the Anatomically Predictive Extension (APE), to extend a partial-body CT image stack using images of a computational human phantom matched to the patient based on their height and weight. To test our method, we created five APE phantoms from chest and abdominal images extracted from the chest-abdomen-pelvis (CAP) CT scans of five patients. Organ doses were calculated for simple chest and prostate irradiations that were planned on the reference computational phantom (assumed patient geometry if no CT images are available), APE phantoms (patient-phantom hybrid given a partial-body patient CT) and full patient CAP CT scans (ground truth). The APE phantoms and patient CAP CT scans resulted in nearly identical dosimetry for those organs that were fully included in the partial-body CT used to construct the APE. The calculated doses to these same organs in the reference phantoms differed by up to 20% and 52% for the chest and prostate cases, respectively. For organs outside the scan coverage, the reference phantom showed, on average, dose differences of 31% (chest case) and 41% (prostate case). For the APE phantoms, these values were 26% (chest) and 17% (prostate). The APE method combines patient and phantom images to improve organ dosimetry both inside and outside the scan range. We intend to use the APE method for estimating dose for organs peripheral to the treatment fields; however, this method is quite generalizable with many potential applications.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6384816PMC
http://dx.doi.org/10.1667/RR14999.1DOI Listing

Publication Analysis

Top Keywords

ape phantoms
16
scan range
12
cap scans
12
novel method
8
extend partial-body
8
dose organs
8
organs scan
8
organ dosimetry
8
ape
8
chest prostate
8

Similar Publications

Introduction: Physical and emotional loss from amputation and associated physical disability are associated with adverse physical and psychological experiences. However, little research, within the Ghanaian context, has focused on the impact of amputation on the well-being of amputees and their caregivers and the coping strategies they use to mitigate challenges experienced. Therefore, the present study explored the impact of amputation on the well-being of amputees and caregivers, and the coping strategies they employ to manage distress associated with amputation and caregiving.

View Article and Find Full Text PDF

Significance: Pulse oximeter measurements are commonly relied upon for managing patient care and thus often require human testing before they can be legally marketed. Recent clinical studies have also identified disparities in their measurement of blood oxygen saturation by race or skin pigmentation.

Aim: The development of a reliable bench-top performance test method based on tissue-simulating phantoms has the potential to facilitate pre-market assessment and the development of more accurate and equitable devices.

View Article and Find Full Text PDF

Ultrasound-induced thermal strain imaging (US-TSI) is a promising ultrasound imaging modality that has been demonstrated in preclinical studies to identify a lipid-rich necrotic core of an atherosclerotic plaque. However, human physiological motion, e.g.

View Article and Find Full Text PDF

The need to quantify brain glutathione (GSH) accurately by J-difference spectroscopy has stimulated assessment of the TE effects on GSH edited signals at the popular field strength 3 T. We performed multiple-TE J-difference MRS at two sites to evaluate the GSH T relaxation and TE dependence of the GSH signal resolution. Two 10-ms spectrally selective Gaussian editing RF pulses were implemented in 3 T MEGA-PRESS sequences at two sites having different vendors.

View Article and Find Full Text PDF

Purpose Of Review: Chronic pain affects approximately 1.5 billion people worldwide, representing the leading cause of disability and a significant financial burden on healthcare systems. Conventional treatments, such as opioids and non-steroidal anti-inflammatory drugs, are frequently linked to adverse effects, including dependency and gastrointestinal issues, and often offer limited long-term relief.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!