  • Unicompartmental knee arthroplasty (UKA) is a surgical option for patients with unicompartmental knee arthritis, and robotic-assisted surgeries aim to enhance precision during these procedures.
  • The study investigates how fast patients can return to work after undergoing robotic-assisted UKA, hypothesizing that recovery time would be quicker compared to total knee arthroplasties (TKAs) and manual UKAs due to better surgical outcomes.
  • Thirty patients undergoing robotic UKA were analyzed for their time to return to work and physical activity levels, utilizing questionnaires and statistical tools to draw conclusions from the data collected post-surgery.

Article Abstract

Introduction: Unicompartmental knee arthroplasty (UKA) is a commonly used procedure for patients suffering from debilitating unicompartmental knee arthritis. For UKA recipients, robotic-assisted surgery has served as an aid in improving surgical accuracy and precision. While studies exist detailing outcomes of robotic UKA, to our knowledge, there are no studies assessing time to return to work using robotic-assisted UKA. Thus, the purpose of this study was to prospectively assess the time to return to work and to achieve the level of work activity following robotic-assisted UKA to create recommendations for patients preoperatively. We hypothesized that the return to work time would be shorter for robotic-assisted UKAs compared with TKAs and manual UKAs, due to more accurate ligament balancing and precise implementation of the operative plan.

Materials And Methods: Thirty consecutive patients scheduled to undergo a robotic-assisted UKA at an academic teaching hospital were prospectively enrolled in the study. Inclusion criteria included employment at the time of surgery, with the intent on returning to the same occupation following surgery and having end-stage knee degenerative joint disease (DJD) limited to the medial compartment. Patients were contacted via email, letter, or phone at two, four, six, and 12 weeks following surgery until they returned to work. The Baecke physical activity questionnaire (BQ) was administered to assess patients' level of activity at work pre- and postoperatively. Statistical analysis was performed using SAS Enterprise Guide (SAS Institute Inc., Cary, North Carolina) and Excel® (Microsoft Corporation, Redmond, Washington). Descriptive statistics were calculated to assess the demographics of the patient population. Boxplots were generated using an Excel® spreadsheet to visualize the BQ scores and a two-tailed t-test was used to assess for differences between pre- and postoperative scores with alpha 0.05.

Results: The mean time to return to work was 6.4 weeks (SD=3.4, range 2-12 weeks), with a median time of six weeks. There was no difference seen in the mean pre- and postoperative BQ scores (2.70 vs. 2.69, respectively; p=0.87).

Conclusion: The findings of the current study suggest that most patients can return to work six weeks following robotic-assisted UKA which appears to be shorter than conventional UKA and TKA. Future level I studies are needed to verify our study findings.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6613386PMC

Publication Analysis

Top Keywords

return work
24
time return
16
robotic-assisted uka
16
unicompartmental knee
12
work
9
work robotic-assisted
8
knee arthroplasty
8
uka
8
pre- postoperative
8
postoperative scores
8