Identification and quantitation of semi-crystalline microplastics using image analysis and differential scanning calorimetry.

Environ Sci Pollut Res Int

Departamento de Desarrollo Tecnológico - DDT, Centro Universitario Regional del Este (CURE), Universidad de la República (UdelaR), Ruta 9 y Ruta 15, 27000, Rocha, Uruguay.

Published: June 2018

AI Article Synopsis

  • The study presents a new method for analyzing microplastics, combining optical microscopy with image analysis (IA) and differential scanning calorimetry (DSC).
  • It focuses on four key synthetic polymers: LDPE, HDPE, PP, and PET, emphasizing techniques for particle characterization, chemical identification, and mass quantification.
  • The findings highlight that particle size significantly influences the reliability of microplastic analysis, affecting both identification and quantification, thus calling for careful sample treatment like sieving.

Article Abstract

There are several techniques used to analyze microplastics. These are often based on a combination of visual and spectroscopic techniques. Here we introduce an alternative workflow for identification and mass quantitation through a combination of optical microscopy with image analysis (IA) and differential scanning calorimetry (DSC). We studied four synthetic polymers with environmental concern: low and high density polyethylene (LDPE and HDPE, respectively), polypropylene (PP), and polyethylene terephthalate (PET). Selected experiments were conducted to investigate (i) particle characterization and counting procedures based on image analysis with open-source software, (ii) chemical identification of microplastics based on DSC signal processing, (iii) dependence of particle size on DSC signal, and (iv) quantitation of microplastics mass based on DSC signal. We describe the potential and limitations of these techniques to increase reliability for microplastic analysis. Particle size demonstrated to have particular incidence in the qualitative and quantitative performance of DSC signals. Both, identification (based on characteristic onset temperature) and mass quantitation (based on heat flow) showed to be affected by particle size. As a result, a proper sample treatment which includes sieving of suspended particles is particularly required for this analytical approach.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s11356-018-1846-0DOI Listing

Publication Analysis

Top Keywords

image analysis
12
dsc signal
12
particle size
12
analysis differential
8
differential scanning
8
scanning calorimetry
8
microplastics based
8
mass quantitation
8
based dsc
8
based
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!