Miniature high frequency ultrasound devices show promise as tools for clinical middle ear and basal cochlea imaging and vibrometry. However, before clinical use it is important to verify that the ultrasound exposure does not damage the cochlea. In this initial study, electrophysiological responses of the cochlea were measured for a range of stimulus frequencies in both ears of anesthetized chinchillas, before and after exposing the organ of Corti region of one ear to pulsed focused ultrasound for 30 min. Measurements were again taken after an 11 day survival period. Cochlear tissue was examined with a confocal microscope for signs of damage to the cochlear hair cells. No significant change in response thresholds due to exposure was found, and no signs of ultrasound-induced tissue damage were observed, although one animal (out of ten) did have a region of extensive tissue damage in the exposed cochlea. However, after further analysis this was concluded to be not likely a result of the ultrasound exposure.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.heares.2017.12.006DOI Listing

Publication Analysis

Top Keywords

high frequency
8
frequency ultrasound
8
initial study
8
ultrasound exposure
8
tissue damage
8
ultrasound
5
prolonged pulsed
4
pulsed high
4
ultrasound imaging
4
imaging basilar
4

Similar Publications

[Eosinophilic esophagitis].

Inn Med (Heidelb)

January 2025

Service de gastro-entérologie et d'hepatologie, Centre hospitalier universitaire vaudois (CHUV), Lausanne, Schweiz.

Eosinophilic esophagitis (EoE) was first described in the early 1990s. Initially a rarity, it is now the most common cause of dysphagia for solid foods in young adults. Its prevalence is estimated to be 1:2000.

View Article and Find Full Text PDF

Purpose: Uncorrected visual impairment (VI) significantly impacts life quality and exacerbates age-related health issues. Social determinants of health (SDOH) are associated with uncorrected VI, but quantitative evidence is limited. This study investigated the link between SDOH and uncorrected VI among aging adults to identify disparities and improve vision care.

View Article and Find Full Text PDF

Objectives: Long-term maintenance of serum urate (SU) levels <6 mg/dl reduces gout flare frequency. However, urate-lowering therapy (ULT) initiation can induce gout flare. The incidence of thromboembolic (TE) and cardiovascular (CV) events has been shown to increase in the 30 and 120 days following gout flare, respectively; therefore, the question of ULT initiation increasing patient risk for CV/TE events has been raised.

View Article and Find Full Text PDF

Human noroviruses are the leading cause of non-bacterial shellfish-associated gastroenteritis. In 2022, a multi-jurisdictional norovirus outbreak associated with contaminated oysters occurred that involved hundreds of illnesses. Here, we conducted genetic analysis on 30 clinical samples associated with this oyster outbreak.

View Article and Find Full Text PDF

We introduce a novel control mode for Scanning Tunneling Microscope (STM) that leverages di/dz feedback. By superimposing a high-frequency sinusoidal modulation on the control signal, we extract the amplitude of the resulting tunneling current to obtain a di/dz measurement as the tip is scanned over the surface. A feedback control loop is then closed to maintain a constant di/dz, enhancing the sensitivity of the tip to subtle surface variations throughout a scan.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!