Postconditioning effects of argon or xenon on early graft function in a porcine model of kidney autotransplantation.

Br J Surg

Laboratory of Abdominal Transplantation, Department of Microbiology and Immunology, KU Leuven, Leuven, Belgium.

Published: July 2018

Background: Ischaemia-reperfusion injury is inevitable during renal transplantation and can lead to delayed graft function and primary non-function. Preconditioning, reconditioning and postconditioning with argon and xenon protects against renal ischaemia-reperfusion injury in rodent models. The hypothesis that postconditioning with argon or xenon inhalation would improve graft function in a porcine renal autotransplant model was tested.

Methods: Pigs (n = 6 per group) underwent left nephrectomy after 60 min of warm ischaemia (renal artery and vein clamping). The procured kidney was autotransplanted in a separate procedure after 18 h of cold storage, immediately after a right nephrectomy. Upon reperfusion, pigs were randomized to inhalation of control gas (70 per cent nitrogen and 30 per cent oxygen), argon (70 per cent and 30 per cent oxygen) or xenon (70 per cent and 30 per cent oxygen) for 2 h. The primary outcome parameter was peak plasma creatinine; secondary outcome parameters included further markers of graft function (creatinine course, urine output), graft injury (aspartate aminotransferase, heart-type fatty acid-binding protein, histology), apoptosis and autophagy (western blot, terminal deoxynucleotidyl transferase dUTP nick-end labelling (TUNEL) staining), inflammatory mediators and markers of cell survival/growth (mRNA and tissue protein quantification), and animal survival. Results are presented as median (i.q.r.). ANOVA and Kruskal-Wallis tests were used where indicated.

Results: Peak plasma creatinine levels were similar between the groups: control 20·8 (16·4-23·1) mg/dl, argon 21·4 (17·1-24·9) mg/dl and xenon 19·4 (17·5-21·0) mg/dl (P = 0·607). Xenon was associated with an increase in autophagy and proapoptotic markers. Creatinine course, urine output, injury markers, histology, survival and inflammatory mediators were not affected by the intervention.

Conclusion: Postconditioning with argon or xenon did not improve kidney graft function in this experimental model. Surgical relevance Ischaemia-reperfusion injury is inevitable during renal transplantation and can lead to delayed graft function and primary non-function. Based on mainly small animal experiments, noble gases (argon and xenon) have been proposed to minimize this ischaemia-reperfusion injury and improve outcomes after transplantation. The hypothesis that postconditioning with argon or xenon inhalation would improve graft function was tested in a porcine kidney autotransplantation model. The peak plasma creatinine concentration was similar in the control, argon and xenon groups. No other secondary outcome parameters, including animal survival, were affected by the intervention. Xenon was associated with an increase in autophagy and proapoptotic markers. Despite promising results in small animal models, postconditioning with argon or xenon in a translational model of kidney autotransplantation was not beneficial. Clinical trials would require better results.

Download full-text PDF

Source
http://dx.doi.org/10.1002/bjs.10796DOI Listing

Publication Analysis

Top Keywords

argon xenon
32
graft function
28
postconditioning argon
20
ischaemia-reperfusion injury
16
xenon
12
kidney autotransplantation
12
70 per cent
12
30 per cent
12
cent oxygen
12
peak plasma
12

Similar Publications

Effect of mechanical stirring on sonoluminescence and sonochemiluminescence.

Ultrason Sonochem

December 2024

Third Institute of Physics, Georg-August-University Göttingen, Friedrich-Hund-Platz 1, 37077 Göttingen, Germany. Electronic address:

Light emissions from cavitating liquids serve as a diagnostic tool for chemical activity, bubble collapse conditions, or excited species. Here we demonstrate the influence of mechanical stirring on sonoluminescence (SL) and sonochemiluminescence (SCL) emissions emerging in the presence of dissolved sodium salts and luminol in different sonicated liquids. In the systems investigated, driven in the 20-40 kHz range, stirring can change the spatial distribution of blue/white broadband SL emissions and of the orange sodium D-line emission, as well as their relative intensities.

View Article and Find Full Text PDF

Xenon and Argon as Neuroprotective Treatments for Perinatal Hypoxic-Ischemic Brain Injury: A Preclinical Systematic Review and Meta-Analysis.

Anesth Analg

October 2024

From the Anaesthetics, Pain Medicine and Intensive Care Division, Department of Surgery and Cancer, Imperial College London, London, United Kingdom.

Xenon and argon are currently being evaluated as potential neuroprotective treatments for acquired brain injuries. Xenon has been evaluated clinically as a treatment for brain ischemia with equivocal results in small trials, but argon has not yet undergone clinical evaluation. Several preclinical studies have investigated xenon or argon as treatments in animal models of perinatal hypoxic-ischemic encephalopathy (HIE).

View Article and Find Full Text PDF

Electron Beam Ion Traps (EBITs) serve as efficient tools for producing and studying highly charged ions. In response to the diagnostic requirements of upcoming magnetic confinement fusion devices, a medium-energy atomic spectra research platform based on a compact EBIT is developed. This platform achieves a central magnetic field of up to 1.

View Article and Find Full Text PDF

The primary objective of this study was to investigate the pharmacokinetics of inhaled argon in young pigs using mechanical ventilation. Also a physiologically based model of argon pharmacokinetics (PBPK) is validated with human data for xenon from the literature and the new data from juvenile pigs. The inherent difficulty in performing pharmacokinetics studies of argon makes the use of the PBPK model especially relevant.

View Article and Find Full Text PDF

The soft ionization mechanism of helium-based plasma seems to be understood while it still remains challenging in argon-based plasma, although many studies have used argon plasmas as a soft ionization source with good ionization efficiencies. In this study, helium, argon, krypton, and xenon were fed into the same discharge geometry, a flexible micro-tube plasma (FµTP), to determine the ionization mechanisms. The FµTPs operated with the named noble gases obtained comparable ionization efficiencies by MS measurements.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!