A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Quality by design-assisted development of a capillary electrophoresis method for the chiral purity determination of dexmedetomidine. | LitMetric

Dexmedetomidine is a selective α -adrenergic agonist used for patient sedation, while its enantiomer levomedetomidine has no sedative effects. As CE has been shown to be a powerful technique for enantiomer analysis, the aim of the study was the quality by design-based development of a CE-based limit test for the enantiomeric impurity levomedetomidine. The analytical target profile was defined that the method should be able to determine levomedetomidine with acceptable precision and accuracy at the 0.1% level. From initial scouting experiments, sulfated β-cyclodextrin was selected as chiral selector. The critical process parameters were identified in a fractional factorial resolution V+ design, while a central composite face centered design and Monte Carlo simulations were used for defining the design space of the method. The selected working conditions were a 21.3/31.5 cm, 50 μm id fused-silica capillary, a 50 mM sodium phosphate buffer, pH 6.5, containing 40 mg/mL sulfated β-cyclodextrin, a capillary temperature of 17°C and an applied voltage of 10 kV. Validation according to the ICH guideline Q2(R1) demonstrated repeatability and intermediate precision of content and migration time between 9.3 and 4.2% with accuracy in the range of 92.0 and 98.9%.

Download full-text PDF

Source
http://dx.doi.org/10.1002/elps.201800100DOI Listing

Publication Analysis

Top Keywords

sulfated β-cyclodextrin
8
quality design-assisted
4
design-assisted development
4
development capillary
4
capillary electrophoresis
4
electrophoresis method
4
method chiral
4
chiral purity
4
purity determination
4
determination dexmedetomidine
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!